The purpose of the present study was to evaluate the presence of five neonicotinoid pesticides, acetamiprid, imidacloprid, clothianidin, thiacloprid, and thiamethoxam, in sheep and cow milk samples collected from animals bred in the Jordan Valley. In this area, numerous citrus plantations are present, and these insecticides are commonly used to protect plants from pests and diseases. Thirty-seven sheep milk samples and 31 cow milk samples were analysed. The analytical method, based on a single cleanup extraction step with SPE cartridges packed with diatomaceous earth material, together with analysis by LC–MS/MS, has guaranteed average recoveries between 75.1% and 88.3%, limits of detection (LOD) and quantification (LOQ) of 0.5 and 1 µg/kg, respectively, for all the five neonicotinoids. LOQ was much lower than the codex maximum residues limits for these pesticides in milks. No residues of the five neonicotinoids were found in any sample at a concentration level above LOD.

LC–MS/MS Analysis of Five Neonicotinoid Pesticides in Sheep and Cow Milk Samples Collected in Jordan Valley / Fedrizzi, Giorgio; Altafini, Alberto; Armorini, Sara; Al-Qudah, Khaled Mefleh; Roncada, Paola*. - In: BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY. - ISSN 0007-4861. - ELETTRONICO. - 102:3(2019), pp. 347-352. [10.1007/s00128-019-02555-8]

LC–MS/MS Analysis of Five Neonicotinoid Pesticides in Sheep and Cow Milk Samples Collected in Jordan Valley

Altafini, Alberto;Armorini, Sara;Roncada, Paola
2019

Abstract

The purpose of the present study was to evaluate the presence of five neonicotinoid pesticides, acetamiprid, imidacloprid, clothianidin, thiacloprid, and thiamethoxam, in sheep and cow milk samples collected from animals bred in the Jordan Valley. In this area, numerous citrus plantations are present, and these insecticides are commonly used to protect plants from pests and diseases. Thirty-seven sheep milk samples and 31 cow milk samples were analysed. The analytical method, based on a single cleanup extraction step with SPE cartridges packed with diatomaceous earth material, together with analysis by LC–MS/MS, has guaranteed average recoveries between 75.1% and 88.3%, limits of detection (LOD) and quantification (LOQ) of 0.5 and 1 µg/kg, respectively, for all the five neonicotinoids. LOQ was much lower than the codex maximum residues limits for these pesticides in milks. No residues of the five neonicotinoids were found in any sample at a concentration level above LOD.
2019
LC–MS/MS Analysis of Five Neonicotinoid Pesticides in Sheep and Cow Milk Samples Collected in Jordan Valley / Fedrizzi, Giorgio; Altafini, Alberto; Armorini, Sara; Al-Qudah, Khaled Mefleh; Roncada, Paola*. - In: BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY. - ISSN 0007-4861. - ELETTRONICO. - 102:3(2019), pp. 347-352. [10.1007/s00128-019-02555-8]
Fedrizzi, Giorgio; Altafini, Alberto; Armorini, Sara; Al-Qudah, Khaled Mefleh; Roncada, Paola*
File in questo prodotto:
File Dimensione Formato  
Jordan milk 2019 R2 per richieste.pdf

accesso aperto

Tipo: Postprint
Licenza: Licenza per accesso libero gratuito
Dimensione 81.11 kB
Formato Adobe PDF
81.11 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/678190
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact