Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
CRIS Current Research Information System
We report on a search for weakly interacting massive particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of (1.30±0.01) ton, resulting in a 1.0 ton yr exposure. The energy region of interest, [1.4,10.6] keVee ([4.9,40.9] keVnr), exhibits an ultralow electron recoil background rate of [82-3+5(syst)±3(stat)] events/(ton yr keVee). No significant excess over background is found, and a profile likelihood analysis parametrized in spatial and energy dimensions excludes new parameter space for the WIMP-nucleon spin-independent elastic scatter cross section for WIMP masses above 6 GeV/c2, with a minimum of 4.1×10-47 cm2 at 30 GeV/c2 and a 90% confidence level.
Dark Matter Search Results from a One Ton-Year Exposure of XENON1T
Aprile, E.;Aalbers, J.;Agostini, F.;Alfonsi, M.;Althueser, L.;Amaro, F. D.;Anthony, M.;Arneodo, F.;Baudis, L.;Bauermeister, B.;Benabderrahmane, M. L.;Berger, T.;Breur, P. A.;Brown, A.;Brown, A.;Brown, E.;Bruenner, S.;Bruno, G.;Budnik, R.;Capelli, C.;Cardoso, J. M. R.;Cichon, D.;Coderre, D.;Colijn, A. P.;Conrad, J.;Cussonneau, J. P.;Decowski, M. P.;De Perio, P.;Di Gangi, P.;Di Giovanni, A.;Diglio, S.;Elykov, A.;Eurin, G.;Fei, J.;Ferella, A. D.;Fieguth, A.;Fulgione, W.;Gallo Rosso, A.;Galloway, M.;Gao, F.;Garbini, M.;Geis, C.;Grandi, L.;Greene, Z.;Qiu, H.;Hasterok, C.;Hogenbirk, E.;Howlett, J.;Itay, R.;Joerg, F.;Kaminsky, B.;Kazama, S.;Kish, A.;Koltman, G.;Landsman, H.;Lang, R. F.;Levinson, L.;Lin, Q.;Lindemann, S.;Lindner, M.;Lombardi, F.;Lopes, J. A. M.;Mahlstedt, J.;Manfredini, A.;Marrodán Undagoitia, T.;Masbou, J.;Masson, D.;Messina, M.;Micheneau, K.;Miller, K.;Molinario, A.;Morå, K.;Murra, M.;Naganoma, J.;Ni, K.;Oberlack, U.;Pelssers, B.;Piastra, F.;Pienaar, J.;Pizzella, V.;Plante, G.;Podviianiuk, R.;Priel, N.;Ramírez García, D.;Rauch, L.;Reichard, S.;Reuter, C.;Riedel, B.;Rizzo, A.;Rocchetti, A.;Rupp, N.;Dos Santos, J. M. F.;Sartorelli, G.;Scheibelhut, M.;Schindler, S.;Schreiner, J.;Schulte, D.;Schumann, M.;Scotto Lavina, L.;Selvi, M.;Shagin, P.;Shockley, E.;Silva, M.;Simgen, H.;Thers, D.;Toschi, F.;Trinchero, G.;Tunnell, C.;Upole, N.;Vargas, M.;Wack, O.;Wang, H.;Wang, Z.;Wei, Y.;Weinheimer, C.;Wittweg, C.;Wulf, J.;Ye, J.;Zhang, Y.;Zhu, T.
2018
Abstract
We report on a search for weakly interacting massive particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of (1.30±0.01) ton, resulting in a 1.0 ton yr exposure. The energy region of interest, [1.4,10.6] keVee ([4.9,40.9] keVnr), exhibits an ultralow electron recoil background rate of [82-3+5(syst)±3(stat)] events/(ton yr keVee). No significant excess over background is found, and a profile likelihood analysis parametrized in spatial and energy dimensions excludes new parameter space for the WIMP-nucleon spin-independent elastic scatter cross section for WIMP masses above 6 GeV/c2, with a minimum of 4.1×10-47 cm2 at 30 GeV/c2 and a 90% confidence level.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/665795
Citazioni
12
1582
1403
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.