Background: The quantification of gait temporal parameters (i.e. step time, stance time) is crucial in human motion analysis and requires the accurate identification of gait events (i.e. heel strike, toe off). With the widespread use of inertial wearable sensors, many algorithms were proposed and applied for the purpose. Nevertheless, only few studies addressed the assessment of the actual performance of these algorithms, rather considering each proposed algorithm as a whole. Research question: How different implementation characteristics influence the assessment of gait events and temporal parameters from inertial sensor measures in terms of accuracy and repeatability? Methods: Seventeen different algorithms were identified from a systematic review and classified based on: 1) sensor position, 2) target variable, 3) computational approach. The influence of these characteristics was analysed on walking data of 35 healthy volunteers mounting 5 tri-axial inertial sensors. Foot contact events identified by 2 force platforms were assumed as gold standard. Temporal parameters were calculated from gait events. Algorithm performance was analysed in terms of accuracy (error median value) and repeatability (error 25th and 75th percentile values). Results: Shank- and foot-based algorithms performed better (in terms of accuracy and repeatability) in gait events detection and stance time estimation than lower trunk-based ones, while sensor position did not affect step estimate, given the error bias characteristics. Angular velocity-based algorithms performed significantly better than acceleration-based ones for toe off detection in terms of repeatability (68 ms and 102 ms, 25th–75th percentile error range, respectively) and, for heel strike detection, showed better repeatability (40 ms and 111 ms) and comparable accuracy (65 ms and 60 ms median error, respectively) than acceleration-based ones. The performance of different computational approaches varied depending on sensor positioning. Significance: Present results support the selection of the proper algorithm for the estimation of gait events and temporal parameters in relation to the specific application.

Analysis of the performance of 17 algorithms from a systematic review: Influence of sensor position, analysed variable and computational approach in gait timing estimation from IMU measurements

Pacini Panebianco, Giulia
;
Bisi, Maria Cristina;Stagni, Rita;Fantozzi, Silvia
2018

Abstract

Background: The quantification of gait temporal parameters (i.e. step time, stance time) is crucial in human motion analysis and requires the accurate identification of gait events (i.e. heel strike, toe off). With the widespread use of inertial wearable sensors, many algorithms were proposed and applied for the purpose. Nevertheless, only few studies addressed the assessment of the actual performance of these algorithms, rather considering each proposed algorithm as a whole. Research question: How different implementation characteristics influence the assessment of gait events and temporal parameters from inertial sensor measures in terms of accuracy and repeatability? Methods: Seventeen different algorithms were identified from a systematic review and classified based on: 1) sensor position, 2) target variable, 3) computational approach. The influence of these characteristics was analysed on walking data of 35 healthy volunteers mounting 5 tri-axial inertial sensors. Foot contact events identified by 2 force platforms were assumed as gold standard. Temporal parameters were calculated from gait events. Algorithm performance was analysed in terms of accuracy (error median value) and repeatability (error 25th and 75th percentile values). Results: Shank- and foot-based algorithms performed better (in terms of accuracy and repeatability) in gait events detection and stance time estimation than lower trunk-based ones, while sensor position did not affect step estimate, given the error bias characteristics. Angular velocity-based algorithms performed significantly better than acceleration-based ones for toe off detection in terms of repeatability (68 ms and 102 ms, 25th–75th percentile error range, respectively) and, for heel strike detection, showed better repeatability (40 ms and 111 ms) and comparable accuracy (65 ms and 60 ms median error, respectively) than acceleration-based ones. The performance of different computational approaches varied depending on sensor positioning. Significance: Present results support the selection of the proper algorithm for the estimation of gait events and temporal parameters in relation to the specific application.
2018
Pacini Panebianco, Giulia*; Bisi, Maria Cristina; Stagni, Rita; Fantozzi, Silvia
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/658031
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 50
  • Scopus 116
  • ???jsp.display-item.citation.isi??? 106
social impact