Motivation: Multiplex readout assays are now increasingly being performed using microfluidic automation in multiwell format. For instance, the Library of Integrated Network-based Cellular Signatures (LINCS) has produced gene expression measurements for tens of thousands of distinct cell perturbations using a 384-well plate format. This dataset is by far the largest 384-well gene expression measurement assay ever performed. We investigated the gene expression profiles of a million samples from the LINCS dataset and found that the vast majority (96%) of the tested plates were affected by a significant 2D spatial bias. Results: Using a novel algorithm combining spatial autocorrelation detection and principal component analysis, we could remove most of the spatial bias from the LINCS dataset and show in parallel a dramatic improvement of similarity between biological replicates assayed in different plates. The proposed methodology is fully general and can be applied to any highly multiplexed assay performed in multiwell format.

Detection and removal of spatial bias in multiwell assays / Lachmann, Alexander; Giorgi, Federico M.; Alvarez, Mariano J.; Califano, Andrea. - In: BIOINFORMATICS. - ISSN 1367-4803. - ELETTRONICO. - 32:13(2016), pp. 1959-1965. [10.1093/bioinformatics/btw092]

Detection and removal of spatial bias in multiwell assays

Giorgi, Federico M.;
2016

Abstract

Motivation: Multiplex readout assays are now increasingly being performed using microfluidic automation in multiwell format. For instance, the Library of Integrated Network-based Cellular Signatures (LINCS) has produced gene expression measurements for tens of thousands of distinct cell perturbations using a 384-well plate format. This dataset is by far the largest 384-well gene expression measurement assay ever performed. We investigated the gene expression profiles of a million samples from the LINCS dataset and found that the vast majority (96%) of the tested plates were affected by a significant 2D spatial bias. Results: Using a novel algorithm combining spatial autocorrelation detection and principal component analysis, we could remove most of the spatial bias from the LINCS dataset and show in parallel a dramatic improvement of similarity between biological replicates assayed in different plates. The proposed methodology is fully general and can be applied to any highly multiplexed assay performed in multiwell format.
2016
Detection and removal of spatial bias in multiwell assays / Lachmann, Alexander; Giorgi, Federico M.; Alvarez, Mariano J.; Califano, Andrea. - In: BIOINFORMATICS. - ISSN 1367-4803. - ELETTRONICO. - 32:13(2016), pp. 1959-1965. [10.1093/bioinformatics/btw092]
Lachmann, Alexander; Giorgi, Federico M.; Alvarez, Mariano J.; Califano, Andrea
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/657604
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 11
social impact