The reliability of low-voltage inverter-fed motors is highly dependent on the inception of partial discharges. The effect of impulsive waveform parameters must be investigated to predict the repetitive partial discharge inception voltage (RPDIV) and define test procedures that can indicate properly the behavior in service of the insulation system. This paper focuses on the RPDIV of magnet wires using twisted pairs subjected to repetitive unipolar impulsive voltage waveforms. The effects of supply frequency (5 to 200 kHz) at pressure levels that are typical for aircraft (20 to 100 kPa) is examined. Results show that RPDIV steadily decreases with frequency up to 100 kHz where it reaches a plateau. This behavior is explained as an effect of the oscillations that inevitably exist in the applied voltage waveform. Therefore, a conservative estimate of the RPDIV could be achieved by raising the supply frequency well above the operation frequency. In the experiments, the RPDIV is decreasing linearly with pressure. If this behavior could be confirmed for other insulation systems, the design of systems working at pressures typical of aircraft would result relatively easy.

Influence of impulse voltage repetition frequency on RPDIV in partial vacuum / Meyer, Doris Ragna*; Cavallini, Andrea; Lusuardi, Luca; Barater, Davide; Pietrini, Giorgio; Soldati, Alessandro. - In: IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION. - ISSN 1070-9878. - STAMPA. - 25:3(2018), pp. 873-882. [10.1109/TDEI.2018.006722]

Influence of impulse voltage repetition frequency on RPDIV in partial vacuum

Cavallini, Andrea;Lusuardi, Luca;
2018

Abstract

The reliability of low-voltage inverter-fed motors is highly dependent on the inception of partial discharges. The effect of impulsive waveform parameters must be investigated to predict the repetitive partial discharge inception voltage (RPDIV) and define test procedures that can indicate properly the behavior in service of the insulation system. This paper focuses on the RPDIV of magnet wires using twisted pairs subjected to repetitive unipolar impulsive voltage waveforms. The effects of supply frequency (5 to 200 kHz) at pressure levels that are typical for aircraft (20 to 100 kPa) is examined. Results show that RPDIV steadily decreases with frequency up to 100 kHz where it reaches a plateau. This behavior is explained as an effect of the oscillations that inevitably exist in the applied voltage waveform. Therefore, a conservative estimate of the RPDIV could be achieved by raising the supply frequency well above the operation frequency. In the experiments, the RPDIV is decreasing linearly with pressure. If this behavior could be confirmed for other insulation systems, the design of systems working at pressures typical of aircraft would result relatively easy.
2018
Influence of impulse voltage repetition frequency on RPDIV in partial vacuum / Meyer, Doris Ragna*; Cavallini, Andrea; Lusuardi, Luca; Barater, Davide; Pietrini, Giorgio; Soldati, Alessandro. - In: IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION. - ISSN 1070-9878. - STAMPA. - 25:3(2018), pp. 873-882. [10.1109/TDEI.2018.006722]
Meyer, Doris Ragna*; Cavallini, Andrea; Lusuardi, Luca; Barater, Davide; Pietrini, Giorgio; Soldati, Alessandro
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/652970
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 54
  • ???jsp.display-item.citation.isi??? 43
social impact