In this paper a control system for shunt active power filters based on an array of proportional-resonant regulators is developed. An important advantage of this topology is the possibility of selective control, namely the possibility to choose the set of current harmonics that has to be compensated. The main contribution of the paper is an algorithm that adaptively changes the voltage saturation of each regulator in order to preserve the control of the fundamental component of the converter current even if the available voltage is not sufficient to control the current harmonics. At the same time, the algorithm tends to improve the quality of the grid current, because it allocates the DC-link voltage of the active power filter in order to focus on the distorting harmonics of the load in proportion to their significance.

Control system for shunt active power filters with adaptive voltage saturation / Amerise, Albino; Mengoni, Michele; Serra, Giovanni; Zarri, Luca; Casadei, Domenico; Tani, Angelo. - ELETTRONICO. - 2017-:(2017), pp. 8095850.682-8095850.687. (Intervento presentato al convegno 9th Annual IEEE Energy Conversion Congress and Exposition, ECCE 2017 tenutosi a usa nel 2017) [10.1109/ECCE.2017.8095850].

Control system for shunt active power filters with adaptive voltage saturation

Amerise, Albino;Mengoni, Michele;Serra, Giovanni;Zarri, Luca;Casadei, Domenico;Tani, Angelo
2017

Abstract

In this paper a control system for shunt active power filters based on an array of proportional-resonant regulators is developed. An important advantage of this topology is the possibility of selective control, namely the possibility to choose the set of current harmonics that has to be compensated. The main contribution of the paper is an algorithm that adaptively changes the voltage saturation of each regulator in order to preserve the control of the fundamental component of the converter current even if the available voltage is not sufficient to control the current harmonics. At the same time, the algorithm tends to improve the quality of the grid current, because it allocates the DC-link voltage of the active power filter in order to focus on the distorting harmonics of the load in proportion to their significance.
2017
2017 IEEE Energy Conversion Congress and Exposition, ECCE 2017
682
687
Control system for shunt active power filters with adaptive voltage saturation / Amerise, Albino; Mengoni, Michele; Serra, Giovanni; Zarri, Luca; Casadei, Domenico; Tani, Angelo. - ELETTRONICO. - 2017-:(2017), pp. 8095850.682-8095850.687. (Intervento presentato al convegno 9th Annual IEEE Energy Conversion Congress and Exposition, ECCE 2017 tenutosi a usa nel 2017) [10.1109/ECCE.2017.8095850].
Amerise, Albino; Mengoni, Michele; Serra, Giovanni; Zarri, Luca; Casadei, Domenico; Tani, Angelo
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/622220
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact