The paper presents a novel mathematical approach for assessing the phase angle displacement of voltages at nods of a power network with respect to a node taken as reference. It is accomplished without the use of a global time-reference signal, like those provided by GPS technology or through wired connections. This study origins from the growing interest of Distribution System Operators (DSOs) to deploy Distributed Synchronized Measurement Systems (DSMS) in their power networks (like, in particular, the Phasor Measurement Units) for enhancing the stability and reliability of the networks. There are circumstances where bringing a time reference signal to remote PMUs is a difficult task. The paper provides an alternative solution to evaluate phasors in Distribution lines with no need of a global time reference.

A novel equivalent power network impedance approach for assessing the time reference in asynchronous measurements / Mingotti, Alessandro; Peretto, Lorenzo; Tinarelli, Roberto. - ELETTRONICO. - (2017), pp. 7969760.1-7969760.6. (Intervento presentato al convegno 2017 IEEE International Instrumentation and Measurement Technology Conference, I2MTC 2017 tenutosi a Torino, Italy nel MAY 22-27, 2017) [10.1109/I2MTC.2017.7969760].

A novel equivalent power network impedance approach for assessing the time reference in asynchronous measurements

MINGOTTI, ALESSANDRO;PERETTO, LORENZO;TINARELLI, ROBERTO
2017

Abstract

The paper presents a novel mathematical approach for assessing the phase angle displacement of voltages at nods of a power network with respect to a node taken as reference. It is accomplished without the use of a global time-reference signal, like those provided by GPS technology or through wired connections. This study origins from the growing interest of Distribution System Operators (DSOs) to deploy Distributed Synchronized Measurement Systems (DSMS) in their power networks (like, in particular, the Phasor Measurement Units) for enhancing the stability and reliability of the networks. There are circumstances where bringing a time reference signal to remote PMUs is a difficult task. The paper provides an alternative solution to evaluate phasors in Distribution lines with no need of a global time reference.
2017
I2MTC 2017 - 2017 IEEE International Instrumentation and Measurement Technology Conference, Proceedings
1
6
A novel equivalent power network impedance approach for assessing the time reference in asynchronous measurements / Mingotti, Alessandro; Peretto, Lorenzo; Tinarelli, Roberto. - ELETTRONICO. - (2017), pp. 7969760.1-7969760.6. (Intervento presentato al convegno 2017 IEEE International Instrumentation and Measurement Technology Conference, I2MTC 2017 tenutosi a Torino, Italy nel MAY 22-27, 2017) [10.1109/I2MTC.2017.7969760].
Mingotti, Alessandro; Peretto, Lorenzo; Tinarelli, Roberto
File in questo prodotto:
File Dimensione Formato  
A novel equivalent.pdf

accesso aperto

Tipo: Postprint
Licenza: Licenza per accesso libero gratuito
Dimensione 521.84 kB
Formato Adobe PDF
521.84 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/607930
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 6
social impact