The bone volume fraction, defined as the Bone-Volume-To-Total-Volume ratio (BV/TV), is an important parameter in the assessment of the bone micro-structure, and is related to the fracture risk in osteoporosis. Although Magnetic Resonance Imaging (MRI) can assess bone micro-architecture parameters in-vivo, high-field whole body MRI scanners are hardly suitable for widescale screening campaigns. Recently, a new NMR application to assess in laboratory the BV/TV of trabecular bone (TB) has been proposed using low-field single-sided NMR. This paper presents an improvement of this technique that allows detection of only the signal from the marrow in the TB suppressing signals from other tissues, which may be present in the sensitive volume of singlesided scanners in a real scenario. The improvement was achieved by filtering signal acquisition by molecular diffusion. Experiments based on an ad-hoc designed Diffusion Weighted T1-T2 pulse sequence have demonstrated that muscle and cartilage signals can be suppressed by using diffusion weighting. On the basis of those experiments, a 1D measurement was established to allow correct estimation of the BV/TV of a TB sample also in the presence of muscle tissue in the sensitive volume of the NMRscanner. The experiments presented, carried out with the NMR-MOUSE PM10 and the NMR-MOLE, exploiting diffusion-weighted pulse sequences, may pave the way for the in-vivo BV/TV evaluation using single-sided scanners.

Single-sided NMR for the diagnosis of osteoporosis: Diffusion weighted pulse sequences for the estimation of trabecular bone volume fraction in the presence of muscle tissue

BARBIERI, MARCO;BRIZI, LEONARDO;BORTOLOTTI, VILLIAM;FANTAZZINI, PAOLA;
In corso di stampa

Abstract

The bone volume fraction, defined as the Bone-Volume-To-Total-Volume ratio (BV/TV), is an important parameter in the assessment of the bone micro-structure, and is related to the fracture risk in osteoporosis. Although Magnetic Resonance Imaging (MRI) can assess bone micro-architecture parameters in-vivo, high-field whole body MRI scanners are hardly suitable for widescale screening campaigns. Recently, a new NMR application to assess in laboratory the BV/TV of trabecular bone (TB) has been proposed using low-field single-sided NMR. This paper presents an improvement of this technique that allows detection of only the signal from the marrow in the TB suppressing signals from other tissues, which may be present in the sensitive volume of singlesided scanners in a real scenario. The improvement was achieved by filtering signal acquisition by molecular diffusion. Experiments based on an ad-hoc designed Diffusion Weighted T1-T2 pulse sequence have demonstrated that muscle and cartilage signals can be suppressed by using diffusion weighting. On the basis of those experiments, a 1D measurement was established to allow correct estimation of the BV/TV of a TB sample also in the presence of muscle tissue in the sensitive volume of the NMRscanner. The experiments presented, carried out with the NMR-MOUSE PM10 and the NMR-MOLE, exploiting diffusion-weighted pulse sequences, may pave the way for the in-vivo BV/TV evaluation using single-sided scanners.
In corso di stampa
Barbieri, M.; Brizi, L.; Bortolotti, V.; Fantazzini, P.; Nogueira d’Eurydice, M.; Obruchkov, S.; Liu, H.; Galvosas, P.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/591939
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
social impact