This paper reports the first turbulence measurements performed in the Long Pipe Facility at the Center for International Cooperation in Long Pipe Experiments (CICLoPE). In particular, the Reynolds stress components obtained from a number of straight and boundary-layer-type single-wire and X-wire probes up to a friction Reynolds number of 3.8 × 104 are reported. In agreement with turbulent boundary-layer experiments as well as with results from the Superpipe, the present measurements show a clear logarithmic region in the streamwise variance profile, with a Townsend-Perry constant of A2 ≈ 1.26. The wall-normal variance profile exhibits a Reynolds-number-independent plateau, while the spanwise component was found to obey a logarithmic scaling over a much wider wall-normal distance than the other two components, with a slope that is nearly half of that of the Townsend-Perry constant, i.e. A2,w ≈ A2/2. The present results therefore provide strong support for the scaling of the Reynolds stress tensor based on the attachededdy hypothesis. Intriguingly, the wall-normal and spanwise components exhibit higher amplitudes than in previous studies, and therefore call for follow-up studies in CICLoPE, as well as other large-scale facilities.

Reynolds stress scaling in pipe flow turbulence - First results from CICLoPE / Örlü, R; Fiorini, T.; Segalini, A.; Bellani, G.; Talamelli, A.; Alfredsson, P.H.. - In: PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES A: MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES. - ISSN 1364-503X. - STAMPA. - 375:2089(2017), pp. 20160187.1-20160187.14. [10.1098/rsta.2016.0187]

Reynolds stress scaling in pipe flow turbulence - First results from CICLoPE

ORLU, RAMIS;FIORINI, TOMMASO;SEGALINI, ANTONIO;BELLANI, GABRIELE;TALAMELLI, ALESSANDRO;
2017

Abstract

This paper reports the first turbulence measurements performed in the Long Pipe Facility at the Center for International Cooperation in Long Pipe Experiments (CICLoPE). In particular, the Reynolds stress components obtained from a number of straight and boundary-layer-type single-wire and X-wire probes up to a friction Reynolds number of 3.8 × 104 are reported. In agreement with turbulent boundary-layer experiments as well as with results from the Superpipe, the present measurements show a clear logarithmic region in the streamwise variance profile, with a Townsend-Perry constant of A2 ≈ 1.26. The wall-normal variance profile exhibits a Reynolds-number-independent plateau, while the spanwise component was found to obey a logarithmic scaling over a much wider wall-normal distance than the other two components, with a slope that is nearly half of that of the Townsend-Perry constant, i.e. A2,w ≈ A2/2. The present results therefore provide strong support for the scaling of the Reynolds stress tensor based on the attachededdy hypothesis. Intriguingly, the wall-normal and spanwise components exhibit higher amplitudes than in previous studies, and therefore call for follow-up studies in CICLoPE, as well as other large-scale facilities.
2017
Reynolds stress scaling in pipe flow turbulence - First results from CICLoPE / Örlü, R; Fiorini, T.; Segalini, A.; Bellani, G.; Talamelli, A.; Alfredsson, P.H.. - In: PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES A: MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES. - ISSN 1364-503X. - STAMPA. - 375:2089(2017), pp. 20160187.1-20160187.14. [10.1098/rsta.2016.0187]
Örlü, R; Fiorini, T.; Segalini, A.; Bellani, G.; Talamelli, A.; Alfredsson, P.H.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/588989
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 65
  • ???jsp.display-item.citation.isi??? 58
social impact