Although hip arthroplasty is an established procedure that relieves pain and improves functions, problems remain with wear and osteolysis. Highly cross-linked polyethylene and Vitamin-E-stabilized polyethylene were introduced in the last years to solve these problems. In this study we compared the in vitro wear behaviour of cross-linked polyethylene (XLPE) versus Vitamin-E diffused XLPE (XLPE_VE) versus conventional ultra-high molecular weight polyethylene (UHMWPE) acetabular cups. The test was performed using a hip joint simulator run for two millions cycles under bovine calf serum as lubricant.Mass loss was found to decrease along the series UHMWPE>XLPE_VE>XLPE, although statistically significant differences were found only between the mass losses of XLPE and UHMWPE at 1.2 and 2 million cycles. The mass loss data were explained in relation to the crystalline morphology of the control unworn cups, as investigated by non-destructive micro-Raman spectroscopy. This technique allowed to disclose a different wear behaviour of the three sets of cups. Wear testing produced a stress-induced crystallisation in UHMWPE, with increases in both amorphous (αa) and orthorhombic (αo) phases at the expense of the third phase (αb), which decreased upon wear. Moreover, the all-trans content decreased, while the ortho-trans content increased, contrarily to the trend observed for XLPE and XLPE_VE, for which no statistically significant changes in αo, αa and αb contents were detected. The XLPE_VE specimens underwent the least significant changes in the spectroscopic markers of micromorphology upon mechanical stress, probably due to their lower starting amorphous content.

The biomaterials challenge: A comparison of polyethylene wear using a hip joint simulator / Affatato, Saverio; Freccero, Nadia; Taddei, Paola. - In: JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS. - ISSN 1751-6161. - STAMPA. - 53:(2016), pp. 40-48. [10.1016/j.jmbbm.2015.08.001]

The biomaterials challenge: A comparison of polyethylene wear using a hip joint simulator

TADDEI, PAOLA
2016

Abstract

Although hip arthroplasty is an established procedure that relieves pain and improves functions, problems remain with wear and osteolysis. Highly cross-linked polyethylene and Vitamin-E-stabilized polyethylene were introduced in the last years to solve these problems. In this study we compared the in vitro wear behaviour of cross-linked polyethylene (XLPE) versus Vitamin-E diffused XLPE (XLPE_VE) versus conventional ultra-high molecular weight polyethylene (UHMWPE) acetabular cups. The test was performed using a hip joint simulator run for two millions cycles under bovine calf serum as lubricant.Mass loss was found to decrease along the series UHMWPE>XLPE_VE>XLPE, although statistically significant differences were found only between the mass losses of XLPE and UHMWPE at 1.2 and 2 million cycles. The mass loss data were explained in relation to the crystalline morphology of the control unworn cups, as investigated by non-destructive micro-Raman spectroscopy. This technique allowed to disclose a different wear behaviour of the three sets of cups. Wear testing produced a stress-induced crystallisation in UHMWPE, with increases in both amorphous (αa) and orthorhombic (αo) phases at the expense of the third phase (αb), which decreased upon wear. Moreover, the all-trans content decreased, while the ortho-trans content increased, contrarily to the trend observed for XLPE and XLPE_VE, for which no statistically significant changes in αo, αa and αb contents were detected. The XLPE_VE specimens underwent the least significant changes in the spectroscopic markers of micromorphology upon mechanical stress, probably due to their lower starting amorphous content.
2016
The biomaterials challenge: A comparison of polyethylene wear using a hip joint simulator / Affatato, Saverio; Freccero, Nadia; Taddei, Paola. - In: JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS. - ISSN 1751-6161. - STAMPA. - 53:(2016), pp. 40-48. [10.1016/j.jmbbm.2015.08.001]
Affatato, Saverio; Freccero, Nadia; Taddei, Paola
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/585109
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 43
  • ???jsp.display-item.citation.isi??? 38
social impact