The vertebral strength and strain can be assessed in vitro by both using isolated vertebrae and sets of three adjacent vertebrae (the central one is loaded through the disks). Our goal was to elucidate if testing single-vertebra-specimens in the elastic regime provides different surface strains to three-vertebrae-segments. Twelve three-vertebrae sets were extracted from thoracolumbar human spines. To measure the principal strains, the central vertebra of each segment was prepared with eight strain-gauges. The sets were tested mechanically, allowing comparison of the surface strains between the two boundary conditions: first when the same vertebra was loaded through the disks (three-vertebrae-segment) and then with the endplates embedded in cement (single-vertebra). They were all subjected to four nondestructive tests (compression, traction, torsion clockwise, and counterclockwise). The magnitude of principal strains differed significantly between the two boundary conditions. For axial loading, the largest principal strains (along vertebral axis) were significantly higher when the same vertebra was tested isolated compared to the three-vertebraesegment. Conversely, circumferential strains decreased significantly in the single vertebrae compared to the three-vertebraesegment, with some variations exceeding 100% of the strain magnitude, including changes from tension to compression. For torsion, the differences between boundary conditions were smaller. This study shows that, in the elastic regime, when the vertebra is loaded through a cement pot, the surface strains differ from when it is loaded through the disks. Therefore, when single vertebrae are tested, surface strain should be taken with caution.

Effect of the in Vitro Boundary Conditions on the Surface Strain Experienced by the Vertebral Body in the Elastic Regime / Danesi, Valentina; Erani, Paolo; Brandolini, Nicola; Juszczyk, MATEUSZ MARIA; Cristofolini, Luca. - In: JOURNAL OF BIOMECHANICAL ENGINEERING. - ISSN 0148-0731. - STAMPA. - 138:10(2016), pp. 104503.1-104503.9. [10.1115/1.4034383]

Effect of the in Vitro Boundary Conditions on the Surface Strain Experienced by the Vertebral Body in the Elastic Regime

DANESI, VALENTINA;JUSZCZYK, MATEUSZ MARIA;CRISTOFOLINI, LUCA
2016

Abstract

The vertebral strength and strain can be assessed in vitro by both using isolated vertebrae and sets of three adjacent vertebrae (the central one is loaded through the disks). Our goal was to elucidate if testing single-vertebra-specimens in the elastic regime provides different surface strains to three-vertebrae-segments. Twelve three-vertebrae sets were extracted from thoracolumbar human spines. To measure the principal strains, the central vertebra of each segment was prepared with eight strain-gauges. The sets were tested mechanically, allowing comparison of the surface strains between the two boundary conditions: first when the same vertebra was loaded through the disks (three-vertebrae-segment) and then with the endplates embedded in cement (single-vertebra). They were all subjected to four nondestructive tests (compression, traction, torsion clockwise, and counterclockwise). The magnitude of principal strains differed significantly between the two boundary conditions. For axial loading, the largest principal strains (along vertebral axis) were significantly higher when the same vertebra was tested isolated compared to the three-vertebraesegment. Conversely, circumferential strains decreased significantly in the single vertebrae compared to the three-vertebraesegment, with some variations exceeding 100% of the strain magnitude, including changes from tension to compression. For torsion, the differences between boundary conditions were smaller. This study shows that, in the elastic regime, when the vertebra is loaded through a cement pot, the surface strains differ from when it is loaded through the disks. Therefore, when single vertebrae are tested, surface strain should be taken with caution.
2016
Effect of the in Vitro Boundary Conditions on the Surface Strain Experienced by the Vertebral Body in the Elastic Regime / Danesi, Valentina; Erani, Paolo; Brandolini, Nicola; Juszczyk, MATEUSZ MARIA; Cristofolini, Luca. - In: JOURNAL OF BIOMECHANICAL ENGINEERING. - ISSN 0148-0731. - STAMPA. - 138:10(2016), pp. 104503.1-104503.9. [10.1115/1.4034383]
Danesi, Valentina; Erani, Paolo; Brandolini, Nicola; Juszczyk, MATEUSZ MARIA; Cristofolini, Luca
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/583641
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact