Transients and repetitive transients affect cable insulation life in a way, which is not easily predictable at the design stage. Therefore, cable system life can be shorter than that expected especially when loads controlled by power electronics are fed, or when HVDC systems are integrated in AC networks. This paper has the purpose to provide a statistical approach to estimate the life of a cable insulation system when repetitive transients, of know probability distribution, are expected to affect insulation during operation. It is shown, using the Miner law and a stochastic approach, that life at a given reliability percentage can be shortened even significantly, depending on transient overvoltage and repetition rate. Condition monitoring, however, remains the main tool to keep track of cable heath condition during operation life.

Partial discharge and aging of AC cable systems under repetitive voltage transient supply / Montanari, Gian Carlo; Fabiani, Davide; Ciani, Fabio. - STAMPA. - (2016), pp. 7548618.379-7548618.382. (Intervento presentato al convegno 34th Electrical Insulation Conference, EIC 2016 tenutosi a Montreal, Canada nel 2016) [10.1109/EIC.2016.7548618].

Partial discharge and aging of AC cable systems under repetitive voltage transient supply

MONTANARI, GIAN CARLO;FABIANI, DAVIDE;
2016

Abstract

Transients and repetitive transients affect cable insulation life in a way, which is not easily predictable at the design stage. Therefore, cable system life can be shorter than that expected especially when loads controlled by power electronics are fed, or when HVDC systems are integrated in AC networks. This paper has the purpose to provide a statistical approach to estimate the life of a cable insulation system when repetitive transients, of know probability distribution, are expected to affect insulation during operation. It is shown, using the Miner law and a stochastic approach, that life at a given reliability percentage can be shortened even significantly, depending on transient overvoltage and repetition rate. Condition monitoring, however, remains the main tool to keep track of cable heath condition during operation life.
2016
34th Electrical Insulation Conference, EIC 2016
379
382
Partial discharge and aging of AC cable systems under repetitive voltage transient supply / Montanari, Gian Carlo; Fabiani, Davide; Ciani, Fabio. - STAMPA. - (2016), pp. 7548618.379-7548618.382. (Intervento presentato al convegno 34th Electrical Insulation Conference, EIC 2016 tenutosi a Montreal, Canada nel 2016) [10.1109/EIC.2016.7548618].
Montanari, Gian Carlo; Fabiani, Davide; Ciani, Fabio
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/576047
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 11
social impact