The aim of the SYRMA-CT collaboration is to set-up the first clinical trial of phase-contrast breast CT with synchrotron radiation (SR). In order to combine high image quality and low delivered dose a number of innovative elements are merged: a CdTe single photon counting detector, state-of-theart CT reconstruction and phase retrieval algorithms. To facilitate an accurate exam optimization, a Monte Carlo model was developed for dose calculation using GEANT4. In this study, high isotropic spatial resolution (120 mu m)(3) CT scans of objects with dimensions and attenuation similar to a human breast were acquired, delivering mean glandular doses in the range of those delivered in clinical breast CT (5-25 mGy). Due to the spatial coherence of the SR beam and the long distance between sample and detector, the images contain, not only absorption, but also phase information from the samples. The application of a phase-retrieval procedure increases the contrast-to-noise ratio of the tomographic images, while the contrast remains almost constant. After applying the simultaneous algebraic reconstruction technique to low-dose phase-retrieved data sets (about 5 mGy) with a reduced number of projections, the spatial resolution was found to be equal to filtered back projection utilizing a four fold higher dose, while the contrast-to-noise ratio was reduced by 30%. These first results indicate the feasibility of clinical breast CT with SR.

Towards breast tomography with synchrotron radiation at Elettra: First images / Longo, R; Arfelli, F; Bellazzini, R; Bottigli, U; Brez, A; Brunetti, A; Delogu, P; Di Lillo, F; Dreossi, D; Fanti, V; Fedon, C; Golosio, B; Lanconelli, N; Mettivier, G; Minuti, M; Oliva, P; Pinchera, M; Rigon, L; Russo, P; Sarno, A; Spandre, G; Tromba, G; Zanconati, F. - In: PHYSICS IN MEDICINE AND BIOLOGY. - ISSN 0031-9155. - STAMPA. - 61:4(2016), pp. 1634-1649. [10.1088/0031-9155/61/4/1634]

Towards breast tomography with synchrotron radiation at Elettra: First images

LANCONELLI, NICO;
2016

Abstract

The aim of the SYRMA-CT collaboration is to set-up the first clinical trial of phase-contrast breast CT with synchrotron radiation (SR). In order to combine high image quality and low delivered dose a number of innovative elements are merged: a CdTe single photon counting detector, state-of-theart CT reconstruction and phase retrieval algorithms. To facilitate an accurate exam optimization, a Monte Carlo model was developed for dose calculation using GEANT4. In this study, high isotropic spatial resolution (120 mu m)(3) CT scans of objects with dimensions and attenuation similar to a human breast were acquired, delivering mean glandular doses in the range of those delivered in clinical breast CT (5-25 mGy). Due to the spatial coherence of the SR beam and the long distance between sample and detector, the images contain, not only absorption, but also phase information from the samples. The application of a phase-retrieval procedure increases the contrast-to-noise ratio of the tomographic images, while the contrast remains almost constant. After applying the simultaneous algebraic reconstruction technique to low-dose phase-retrieved data sets (about 5 mGy) with a reduced number of projections, the spatial resolution was found to be equal to filtered back projection utilizing a four fold higher dose, while the contrast-to-noise ratio was reduced by 30%. These first results indicate the feasibility of clinical breast CT with SR.
2016
Towards breast tomography with synchrotron radiation at Elettra: First images / Longo, R; Arfelli, F; Bellazzini, R; Bottigli, U; Brez, A; Brunetti, A; Delogu, P; Di Lillo, F; Dreossi, D; Fanti, V; Fedon, C; Golosio, B; Lanconelli, N; Mettivier, G; Minuti, M; Oliva, P; Pinchera, M; Rigon, L; Russo, P; Sarno, A; Spandre, G; Tromba, G; Zanconati, F. - In: PHYSICS IN MEDICINE AND BIOLOGY. - ISSN 0031-9155. - STAMPA. - 61:4(2016), pp. 1634-1649. [10.1088/0031-9155/61/4/1634]
Longo, R; Arfelli, F; Bellazzini, R; Bottigli, U; Brez, A; Brunetti, A; Delogu, P; Di Lillo, F; Dreossi, D; Fanti, V; Fedon, C; Golosio, B; Lanconelli, N; Mettivier, G; Minuti, M; Oliva, P; Pinchera, M; Rigon, L; Russo, P; Sarno, A; Spandre, G; Tromba, G; Zanconati, F
File in questo prodotto:
File Dimensione Formato  
11585_564503_postprint.pdf

accesso aperto

Tipo: Postprint
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione - Non commerciale - Non opere derivate (CCBYNCND)
Dimensione 7.57 MB
Formato Adobe PDF
7.57 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/564503
Citazioni
  • ???jsp.display-item.citation.pmc??? 22
  • Scopus 75
  • ???jsp.display-item.citation.isi??? 65
social impact