Background: This study describes the pattern of ultrasonographic contrast enhancement of the pancreatic body and left lobe using a second-generation commercial contrast medium (Sonovue) in 10 clinically healthy cats. Results: Following contrast medium administration, microbubbles were observed within the splenic artery. This was followed by an inflow of contrast medium into the pancreatic capillary beds, providing a uniformly contrast-enhanced pancreas at peak intensity (PI). At the time of PI, a replenishment of the splenic and portal veins started and increased progressively during the wash-out phase. During the wash-out phase, the echogenicity of the pancreatic parenchyma decreased progressively. Perfusion parameters included arrival time (4.69 ± 1.26 s), time to peak from injection (7.52 ± 1.88 s), time to peak from initial rise (2.84 ± 0.88 s), peak intensity (6.58 ± 2.66 a.u.), and wash-in rate (2.11 ± 1.79 a.u./s). Conclusions: This perfusion pattern of normal pancreatic parenchyma may be useful for characterising cats with exocrine pancreatic disorders.

Contrast-enhanced ultrasonography of the pancreas in healthy cats / Diana, Alessia; Linta, Nikolina; Cipone, Mario; Fedone, Valeria; Steiner, Joerg M; Fracassi, Federico; Grandis, Annamaria; Barontoaldo, Marco. - In: BMC VETERINARY RESEARCH. - ISSN 1746-6148. - ELETTRONICO. - 11:(2015), pp. 64.1-64.7. [10.1186/s12917-015-0380-2]

Contrast-enhanced ultrasonography of the pancreas in healthy cats

DIANA, ALESSIA;LINTA, NIKOLINA;CIPONE, MARIO;FRACASSI, FEDERICO;GRANDIS, ANNAMARIA;BARON TOALDO, MARCO
2015

Abstract

Background: This study describes the pattern of ultrasonographic contrast enhancement of the pancreatic body and left lobe using a second-generation commercial contrast medium (Sonovue) in 10 clinically healthy cats. Results: Following contrast medium administration, microbubbles were observed within the splenic artery. This was followed by an inflow of contrast medium into the pancreatic capillary beds, providing a uniformly contrast-enhanced pancreas at peak intensity (PI). At the time of PI, a replenishment of the splenic and portal veins started and increased progressively during the wash-out phase. During the wash-out phase, the echogenicity of the pancreatic parenchyma decreased progressively. Perfusion parameters included arrival time (4.69 ± 1.26 s), time to peak from injection (7.52 ± 1.88 s), time to peak from initial rise (2.84 ± 0.88 s), peak intensity (6.58 ± 2.66 a.u.), and wash-in rate (2.11 ± 1.79 a.u./s). Conclusions: This perfusion pattern of normal pancreatic parenchyma may be useful for characterising cats with exocrine pancreatic disorders.
2015
Contrast-enhanced ultrasonography of the pancreas in healthy cats / Diana, Alessia; Linta, Nikolina; Cipone, Mario; Fedone, Valeria; Steiner, Joerg M; Fracassi, Federico; Grandis, Annamaria; Barontoaldo, Marco. - In: BMC VETERINARY RESEARCH. - ISSN 1746-6148. - ELETTRONICO. - 11:(2015), pp. 64.1-64.7. [10.1186/s12917-015-0380-2]
Diana, Alessia; Linta, Nikolina; Cipone, Mario; Fedone, Valeria; Steiner, Joerg M; Fracassi, Federico; Grandis, Annamaria; Barontoaldo, Marco
File in questo prodotto:
File Dimensione Formato  
CEUS PANCREAS _Article_380.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 3.43 MB
Formato Adobe PDF
3.43 MB Adobe PDF Visualizza/Apri