This work presents a new PD (partial discharge) measuring system for inverter-fed motors based on a bridge circuit topology. The bridge circuit was adopted in the measuring system for picking up PD signal and suppressing interference. The experimental results show that it is possible to detect and record PD notwithstanding the large interference due to inverter commutations if measuring frequencies are selected adequately

Frequency and time-domain analysis of partial discharge measurements in PWM inverter-fed induction motors

CAVALLINI, ANDREA;MONTANARI, GIAN CARLO
2005

Abstract

This work presents a new PD (partial discharge) measuring system for inverter-fed motors based on a bridge circuit topology. The bridge circuit was adopted in the measuring system for picking up PD signal and suppressing interference. The experimental results show that it is possible to detect and record PD notwithstanding the large interference due to inverter commutations if measuring frequencies are selected adequately
2005
IPEMC 2004 : The 4th International Power Electronics and Motion Control Conference : conference proceedings
661
663
Yu Q.; Cavallini A.; Montanari G.C.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/5429
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 0
social impact