Purpose: This study aims at assessing if, and to what extent, removing from blood flow (BF) maps those values based on the error underlying their computation, allows highlighting significant differences in perfusion of squamous cell carcinoma (SCC) and adenocarcinoma (ADK). Methods and Materials: Six SCC and twenty-eight ADK referring to thirty-four patients who underwent a CT perfusion (CTp) at the diagnosis stage, were considered in this study. BF values were computed according to the maximum slope method. Also, BF values arising from time-concentration curves with high fitting errors have been automatically removed, yielding corrected maps. Finally, sixty-eight couples of corrected and uncorrected BF maps were achieved. Five features from first-order statistics were computed on each BF map and the differences between SCC and ADK were assessed through the one-tail Welch's t-test (p-value<0.01). Results: Differences in BF values between SCC and ADK groups are not detected with uncorrected perfusion maps. On the contrary, significant differences were highlighted by kurtosis, using corrected maps. In particular, at baseline, perfusion values of the SCC subtype (mean BF=62.2) shows a kurtosis significantly greater (p=0.003) than that of the ADK (mean BF=89.6). Conclusions: The correction of BF maps emphasizes functional features of these cancer subtypes. In particular, before starting therapy SCC has significantly smaller BF values, pointing out the presence of wide necrotic regions, while ADK BF values are generally higher and more heterogeneous. These findings should be considered for planning optimization of the anti-angiogenic therapies, assessed with CTp, thus encouraging its use in clinic.

Improvement of perfusion characterisation in two lung tumour subtypes using de-noised CT perfusion maps / S. Baiocco; D. Barone; G. Gavelli; A. Bevilacqua. - In: INSIGHTS INTO IMAGING. - ISSN 1869-4101. - ELETTRONICO. - 7:1 (Suppl)(2016), pp. 256-256. (Intervento presentato al convegno The 28th European Congress of Radiology (ECR 2016) tenutosi a Vienna (Austria) nel March 2-6, 2016).

Improvement of perfusion characterisation in two lung tumour subtypes using de-noised CT perfusion maps

BAIOCCO, SERENA;GAVELLI, GIAMPAOLO;BEVILACQUA, ALESSANDRO
2016

Abstract

Purpose: This study aims at assessing if, and to what extent, removing from blood flow (BF) maps those values based on the error underlying their computation, allows highlighting significant differences in perfusion of squamous cell carcinoma (SCC) and adenocarcinoma (ADK). Methods and Materials: Six SCC and twenty-eight ADK referring to thirty-four patients who underwent a CT perfusion (CTp) at the diagnosis stage, were considered in this study. BF values were computed according to the maximum slope method. Also, BF values arising from time-concentration curves with high fitting errors have been automatically removed, yielding corrected maps. Finally, sixty-eight couples of corrected and uncorrected BF maps were achieved. Five features from first-order statistics were computed on each BF map and the differences between SCC and ADK were assessed through the one-tail Welch's t-test (p-value<0.01). Results: Differences in BF values between SCC and ADK groups are not detected with uncorrected perfusion maps. On the contrary, significant differences were highlighted by kurtosis, using corrected maps. In particular, at baseline, perfusion values of the SCC subtype (mean BF=62.2) shows a kurtosis significantly greater (p=0.003) than that of the ADK (mean BF=89.6). Conclusions: The correction of BF maps emphasizes functional features of these cancer subtypes. In particular, before starting therapy SCC has significantly smaller BF values, pointing out the presence of wide necrotic regions, while ADK BF values are generally higher and more heterogeneous. These findings should be considered for planning optimization of the anti-angiogenic therapies, assessed with CTp, thus encouraging its use in clinic.
2016
Book of Abstracts - B - Scientific abstracts
256
256
Improvement of perfusion characterisation in two lung tumour subtypes using de-noised CT perfusion maps / S. Baiocco; D. Barone; G. Gavelli; A. Bevilacqua. - In: INSIGHTS INTO IMAGING. - ISSN 1869-4101. - ELETTRONICO. - 7:1 (Suppl)(2016), pp. 256-256. (Intervento presentato al convegno The 28th European Congress of Radiology (ECR 2016) tenutosi a Vienna (Austria) nel March 2-6, 2016).
S. Baiocco; D. Barone; G. Gavelli; A. Bevilacqua
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/533156
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact