PURPOSE: The aim of the study was to compare both reproducibility and prognostic value of lesion size measurements obtained manually and semiautomatically on computed tomography in advanced non-small cell lung cancer (NSCLC). MATERIALS AND METHODS: Manual axial longest diameter, semiautomatic axial longest diameter, and volume of NSCLC lesions were independently analyzed by 4 readers at baseline and after at least 1 cycle of platinum-based chemotherapy. The prognostic value of the proportional change in lesion size between baseline and follow-up CT was evaluated using either RECIST or experimental thresholds derived from the quartiles of the changes as assessed manually or semiautomatically. RESULTS: Semiautomatic axial longest diameter (concordance correlation coefficient [CCC]: 0.980 to 0.987; variation coefficient [VC%]: 6% to 7.3%) and volume (CCC: 0.974 to 0.991; VC%: 5.6% to 9.5%) were more reproducible than manual axial longest diameter (CCC: 0.950 to 0.984; VC%: 6.4% to 11.7%). RECIST categories did not stratify patients with different survival durations. For 3/4 readers, a decrease of ≤ 70% in lesion volume was associated with shorter survival (median survival: 11 mo, P < 0.05; hazard ratio: 5 to 22.2, P < 0.05). CONCLUSIONS: In advanced NSCLC, semiautomatic measures were more reproducible than manual diameter, and volumetric measurement may better predict patient survival.

Semiautomatic analysis on computed tomography in locally advanced or metastatic non-small cell lung cancer

DICIOTTI, STEFANO;
2015

Abstract

PURPOSE: The aim of the study was to compare both reproducibility and prognostic value of lesion size measurements obtained manually and semiautomatically on computed tomography in advanced non-small cell lung cancer (NSCLC). MATERIALS AND METHODS: Manual axial longest diameter, semiautomatic axial longest diameter, and volume of NSCLC lesions were independently analyzed by 4 readers at baseline and after at least 1 cycle of platinum-based chemotherapy. The prognostic value of the proportional change in lesion size between baseline and follow-up CT was evaluated using either RECIST or experimental thresholds derived from the quartiles of the changes as assessed manually or semiautomatically. RESULTS: Semiautomatic axial longest diameter (concordance correlation coefficient [CCC]: 0.980 to 0.987; variation coefficient [VC%]: 6% to 7.3%) and volume (CCC: 0.974 to 0.991; VC%: 5.6% to 9.5%) were more reproducible than manual axial longest diameter (CCC: 0.950 to 0.984; VC%: 6.4% to 11.7%). RECIST categories did not stratify patients with different survival durations. For 3/4 readers, a decrease of ≤ 70% in lesion volume was associated with shorter survival (median survival: 11 mo, P < 0.05; hazard ratio: 5 to 22.2, P < 0.05). CONCLUSIONS: In advanced NSCLC, semiautomatic measures were more reproducible than manual diameter, and volumetric measurement may better predict patient survival.
2015
Colombi, Davide; Manna, Carmelinda; Montermini, Ilaria; Seletti, Valeria; Diciotti, Stefano; Tiseo, Marcello; Fontana, Elisa; De Filippo, Massimo; Silva, Mario; Sverzellati, Nicola
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/523812
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 2
social impact