A joint UNIFE-UNIBO experimental campaign was conducted to assess the feasibility of short-lived radioisotope (SLR) production within the pulsed discharges of a Plasma Focus (PF) device. This so-called “endogenous production” technique rests on the exploitation of nuclear reactions for the creation of SLR directly within the plasma, rather than on irradiating an external target. Until now only one research group (in the USA) has published data relevant to PF endogenous production of SLR, and the data seem to confirm that the PF has the capability to breed SLR. The UNIFE-UNIBO campaign demonstrated production of 15O, 17F and 13N from the 14N(d,n)15O, 12C(d,n)13N and 16O(d,n)17F reactions. A 7 kJ, 17 kV Mather-type PF was operated with natural nitrogen, oxygen, CO2 and deuterium in the vacuum chamber. Results to date confirm that, with a PF of this type, up to 1 microCi of SLRs per discharge can be obtained.

Preliminary Results on the Production of Short-Lived Radioisotopes with a Plasma Focus Device / E. Angeli; A. Tartari; M. Frignani; D. Mostacci; F. Rocchi; M. Sumini. - In: APPLIED RADIATION AND ISOTOPES. - ISSN 0969-8043. - STAMPA. - 63:(2005), pp. 545-551. [10.1016/j.apradiso.2005.05.003]

Preliminary Results on the Production of Short-Lived Radioisotopes with a Plasma Focus Device

MOSTACCI, DOMIZIANO;SUMINI, MARCO
2005

Abstract

A joint UNIFE-UNIBO experimental campaign was conducted to assess the feasibility of short-lived radioisotope (SLR) production within the pulsed discharges of a Plasma Focus (PF) device. This so-called “endogenous production” technique rests on the exploitation of nuclear reactions for the creation of SLR directly within the plasma, rather than on irradiating an external target. Until now only one research group (in the USA) has published data relevant to PF endogenous production of SLR, and the data seem to confirm that the PF has the capability to breed SLR. The UNIFE-UNIBO campaign demonstrated production of 15O, 17F and 13N from the 14N(d,n)15O, 12C(d,n)13N and 16O(d,n)17F reactions. A 7 kJ, 17 kV Mather-type PF was operated with natural nitrogen, oxygen, CO2 and deuterium in the vacuum chamber. Results to date confirm that, with a PF of this type, up to 1 microCi of SLRs per discharge can be obtained.
2005
Preliminary Results on the Production of Short-Lived Radioisotopes with a Plasma Focus Device / E. Angeli; A. Tartari; M. Frignani; D. Mostacci; F. Rocchi; M. Sumini. - In: APPLIED RADIATION AND ISOTOPES. - ISSN 0969-8043. - STAMPA. - 63:(2005), pp. 545-551. [10.1016/j.apradiso.2005.05.003]
E. Angeli; A. Tartari; M. Frignani; D. Mostacci; F. Rocchi; M. Sumini
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/5092
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 29
  • ???jsp.display-item.citation.isi??? 30
social impact