We developed monolithic active pixel detectors that exploit the triple well option of CMOS 130nm technology to implement analog and digital signal processing at the pixel level. The charge collecting element is realized using the deep N-well (DNW) and partially overlaps the analog circuit. With this scheme we were able to implement a full in-pixel signal processing chain, composed of a charge preamplifier, shaper, discriminator, and latch. This approach has been validated by a first prototype (APSEL0), and we report here on the extensive measurements performed on the second prototype (APSEL1), containing various single pixel structures with analog readout and an 8×8 matrix of 50 × 50 μm2 pixels with sequential digital readout. For 900 μm2 pixels the equivalent noise charge has been measured to be 40 e−, with a S/N ratio of about 30 for the 55Fe 5.9 keV signal. The matrix readout has been tested up to 30 MHz and the crosstalk between pixels characterized. The threshold dispersion and the noise of the pixels in the matrix have been measured through noise scans. These measurements confirm the viability of the triple well process for MAPS fabrication, and indicate the design improvements for the next prototype chip (APSEL2).

Development of 130nm CMOS Monolithic Active Pixels with In-pixel Signal Processing / F. Forti; C. Andreoli; G. Batignani; S. Bettarini; F. Bosi; L. Bosisio; M. Bruschi; G. Calderini; R. Cenci; G.F. Dalla Betta; M. Dell’Orso; G. Fontana; A. Gabrielli; D. Gamba; B. Giacobbe; G. Giacomini; P. Giannetti; M.A. Giorgi; G. Giraudo; L. Lanceri; A. Lusiani; M. Manghisoni; G. Marchiori; P. Mereu; F. Morsani; N. Neri; L. Pancheri; E. Paoloni; E. Pozzati; I. Rachevskaia; L. Ratti; V. Re; G. Rizzo; N. Semprini; G. Soncini; R. Spighi; V. Speziali; G. Traversi; J. Walsh; G. Verzellesi; L. Vitale; M. Villa; A. Zoccoli. - STAMPA. - (2006), pp. 1456-1459. (Intervento presentato al convegno 2006 Nuclear Science Symposium, Medical Imaging Conference and 15th International Room Temperature Semiconductor Detector Workshop tenutosi a San Diego, California nel October 29 – Nov. 4, 2006).

Development of 130nm CMOS Monolithic Active Pixels with In-pixel Signal Processing

GABRIELLI, ALESSANDRO;SEMPRINI CESARI, NICOLA;VILLA, MAURO;ZOCCOLI, ANTONIO
2006

Abstract

We developed monolithic active pixel detectors that exploit the triple well option of CMOS 130nm technology to implement analog and digital signal processing at the pixel level. The charge collecting element is realized using the deep N-well (DNW) and partially overlaps the analog circuit. With this scheme we were able to implement a full in-pixel signal processing chain, composed of a charge preamplifier, shaper, discriminator, and latch. This approach has been validated by a first prototype (APSEL0), and we report here on the extensive measurements performed on the second prototype (APSEL1), containing various single pixel structures with analog readout and an 8×8 matrix of 50 × 50 μm2 pixels with sequential digital readout. For 900 μm2 pixels the equivalent noise charge has been measured to be 40 e−, with a S/N ratio of about 30 for the 55Fe 5.9 keV signal. The matrix readout has been tested up to 30 MHz and the crosstalk between pixels characterized. The threshold dispersion and the noise of the pixels in the matrix have been measured through noise scans. These measurements confirm the viability of the triple well process for MAPS fabrication, and indicate the design improvements for the next prototype chip (APSEL2).
2006
2006 Nuclear Science Symposium, Medical Imaging Conference and 15th International Room Temperature Semiconductor Detector Workshop
1456
1459
Development of 130nm CMOS Monolithic Active Pixels with In-pixel Signal Processing / F. Forti; C. Andreoli; G. Batignani; S. Bettarini; F. Bosi; L. Bosisio; M. Bruschi; G. Calderini; R. Cenci; G.F. Dalla Betta; M. Dell’Orso; G. Fontana; A. Gabrielli; D. Gamba; B. Giacobbe; G. Giacomini; P. Giannetti; M.A. Giorgi; G. Giraudo; L. Lanceri; A. Lusiani; M. Manghisoni; G. Marchiori; P. Mereu; F. Morsani; N. Neri; L. Pancheri; E. Paoloni; E. Pozzati; I. Rachevskaia; L. Ratti; V. Re; G. Rizzo; N. Semprini; G. Soncini; R. Spighi; V. Speziali; G. Traversi; J. Walsh; G. Verzellesi; L. Vitale; M. Villa; A. Zoccoli. - STAMPA. - (2006), pp. 1456-1459. (Intervento presentato al convegno 2006 Nuclear Science Symposium, Medical Imaging Conference and 15th International Room Temperature Semiconductor Detector Workshop tenutosi a San Diego, California nel October 29 – Nov. 4, 2006).
F. Forti; C. Andreoli; G. Batignani; S. Bettarini; F. Bosi; L. Bosisio; M. Bruschi; G. Calderini; R. Cenci; G.F. Dalla Betta; M. Dell’Orso; G. Fontana; A. Gabrielli; D. Gamba; B. Giacobbe; G. Giacomini; P. Giannetti; M.A. Giorgi; G. Giraudo; L. Lanceri; A. Lusiani; M. Manghisoni; G. Marchiori; P. Mereu; F. Morsani; N. Neri; L. Pancheri; E. Paoloni; E. Pozzati; I. Rachevskaia; L. Ratti; V. Re; G. Rizzo; N. Semprini; G. Soncini; R. Spighi; V. Speziali; G. Traversi; J. Walsh; G. Verzellesi; L. Vitale; M. Villa; A. Zoccoli
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/47347
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 2
social impact