The neutron capture cross section of U-238 is fundamental to the design and operation of current reactors and future fast nuclear reactors, and thus must be measured to a high level of accuracy. An experiment has been performed at the CERN n_TOF facility using a 4 pi Total Absorption Calorimeter (TAC) to measure the capture cross section in the resolved resonance region between 1 eV and 25 keV. A preliminary analysis of the TAC data is presented with particular emphasis to the experimental background in this energy region of interest.
High-precision Measurement of the U-238(n,gamma) Cross Section with the Total Absorption Calorimeter (TAC) at n_TOF, CERN / Massimi, C.; Mingrone, F.; Vannini, G.. - In: NUCLEAR DATA SHEETS. - ISSN 0090-3752. - STAMPA. - 119:(2014), pp. E26-E30.
High-precision Measurement of the U-238(n,gamma) Cross Section with the Total Absorption Calorimeter (TAC) at n_TOF, CERN
MASSIMI, CRISTIAN;MINGRONE, FEDERICA;VANNINI, GIANNI
2014
Abstract
The neutron capture cross section of U-238 is fundamental to the design and operation of current reactors and future fast nuclear reactors, and thus must be measured to a high level of accuracy. An experiment has been performed at the CERN n_TOF facility using a 4 pi Total Absorption Calorimeter (TAC) to measure the capture cross section in the resolved resonance region between 1 eV and 25 keV. A preliminary analysis of the TAC data is presented with particular emphasis to the experimental background in this energy region of interest.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.