The purpose was to compare the dosimetric results observed in 201 breast cancer patients submitted to tangential forward intensity-modulated radiation therapy (IMRT) with those observed in 131 patients treated with a standard wedged 3D technique for postoperative treatment of whole breast, according to breast size and supraclavicular node irradiation. Following dosimetric parameters were used for the comparison: D(max), D(min), D(mean), V(95%) and V(107%) for the irradiated volume; D(max), D(mean), V(80%) and V(95%) for the ipsilateral lung; D(max), D(mean), V(80%) and V(95%) for the heart. Stratification was made according to breast size and supraclavicular (SCV) nodal irradiation. As respect to irradiated volume, a significant reduction of V(107%) (mean values: 7.0 ± 6.6 versus 2.4 ± 3.7, p < 0.001) and D(max) (mean % values: 111.2 ± 2.7 versus 107.7 ± 6.3, p < 0.001), and an increase of D(min) (mean % values: 65.0 ± 17.4 versus 74.9 ± 12.9, p < 0.001) were observed with forward IMRT. The homogeneity of dose distribution to target volume significantly improved with forward IMRT in all patient groups, irrespective of breast size or supraclavicular nodal irradiation. When patients treated with supraclavicular nodal irradiation were excluded from the analysis, forward IMRT slightly reduced V(80%) (mean values: 3.7 ± 2.6 versus 3.0 ± 2.4, p = 0.03) and V(95%) (mean values 1.9 ± 1.8 versus 1.2%± 1.5; p = 0.001) of the ipsilateral lung. The dose to the heart tended to be lower with IMRT but this difference was not statistically significant. Tangential forward IMRT in postoperative treatment of whole breast improved dosimetric parameters in terms of homogeneity of dose distribution to the target in a large sample of patients, independent of breast size or supraclavicular nodal irradiation. Lung irradiation was slightly reduced in patients not undergoing to supraclavicular irradiation.

Forward planned intensity modulated radiotherapy (IMRT) for whole breast postoperative radiotherapy. Is it useful? When? / MORGANTI AG; CILLA S; DE GAETANO AM; PANUNZI S; DIGESU' C; MACCHIA G; MASSACCESI M; DEODATO F; FERRANDINA G; CELLINI N; SCAMBIA G; PIERMATTEI A; VALENTINI V. - In: JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS. - ISSN 1526-9914. - ELETTRONICO. - 12:2(2011), pp. 3451-3460.

Forward planned intensity modulated radiotherapy (IMRT) for whole breast postoperative radiotherapy. Is it useful? When?

MORGANTI, ALESSIO GIUSEPPE;
2011

Abstract

The purpose was to compare the dosimetric results observed in 201 breast cancer patients submitted to tangential forward intensity-modulated radiation therapy (IMRT) with those observed in 131 patients treated with a standard wedged 3D technique for postoperative treatment of whole breast, according to breast size and supraclavicular node irradiation. Following dosimetric parameters were used for the comparison: D(max), D(min), D(mean), V(95%) and V(107%) for the irradiated volume; D(max), D(mean), V(80%) and V(95%) for the ipsilateral lung; D(max), D(mean), V(80%) and V(95%) for the heart. Stratification was made according to breast size and supraclavicular (SCV) nodal irradiation. As respect to irradiated volume, a significant reduction of V(107%) (mean values: 7.0 ± 6.6 versus 2.4 ± 3.7, p < 0.001) and D(max) (mean % values: 111.2 ± 2.7 versus 107.7 ± 6.3, p < 0.001), and an increase of D(min) (mean % values: 65.0 ± 17.4 versus 74.9 ± 12.9, p < 0.001) were observed with forward IMRT. The homogeneity of dose distribution to target volume significantly improved with forward IMRT in all patient groups, irrespective of breast size or supraclavicular nodal irradiation. When patients treated with supraclavicular nodal irradiation were excluded from the analysis, forward IMRT slightly reduced V(80%) (mean values: 3.7 ± 2.6 versus 3.0 ± 2.4, p = 0.03) and V(95%) (mean values 1.9 ± 1.8 versus 1.2%± 1.5; p = 0.001) of the ipsilateral lung. The dose to the heart tended to be lower with IMRT but this difference was not statistically significant. Tangential forward IMRT in postoperative treatment of whole breast improved dosimetric parameters in terms of homogeneity of dose distribution to the target in a large sample of patients, independent of breast size or supraclavicular nodal irradiation. Lung irradiation was slightly reduced in patients not undergoing to supraclavicular irradiation.
2011
Forward planned intensity modulated radiotherapy (IMRT) for whole breast postoperative radiotherapy. Is it useful? When? / MORGANTI AG; CILLA S; DE GAETANO AM; PANUNZI S; DIGESU' C; MACCHIA G; MASSACCESI M; DEODATO F; FERRANDINA G; CELLINI N; SCAMBIA G; PIERMATTEI A; VALENTINI V. - In: JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS. - ISSN 1526-9914. - ELETTRONICO. - 12:2(2011), pp. 3451-3460.
MORGANTI AG; CILLA S; DE GAETANO AM; PANUNZI S; DIGESU' C; MACCHIA G; MASSACCESI M; DEODATO F; FERRANDINA G; CELLINI N; SCAMBIA G; PIERMATTEI A; VALENTINI V
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/388932
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 38
  • ???jsp.display-item.citation.isi??? 32
social impact