The aim of the present study was to investigation in vitro the effect of deficient bone-implant contact on the primary stability of a straight conical stem. Various possible deficient contact patterns were derived from surgical simulations. The effect of stair climbing loads on the bone-implant micromotion was firstly investigated using a finite element model and then an in vitro test aimed at assessing primary stability. It was found that if the surface features are prevented from biting dense bone in a few small but critical regions, stem primary stability is completely lost. These results suggest that the surface features used in the axisymmetric stem under investigation can be too sensitive to deficient contact conditions, and thus should be augmented with additional antirotational fins. Preliminary tests showed that a stem with the addition of such fins presents good primary stability in all tested conditions.

On the biomechanical stability of cementless straight conical hip stems / Viceconti M.; Pancanti A.; Varini E.; Traina F.; Cristofolini L.. - In: PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS. PART H, JOURNAL OF ENGINEERING IN MEDICINE. - ISSN 0954-4119. - STAMPA. - 220:3(2006), pp. 473-480. [10.1243/09544119H06904]

On the biomechanical stability of cementless straight conical hip stems

VICECONTI, MARCO;VARINI, ELENA;TRAINA, FRANCESCO;CRISTOFOLINI, LUCA
2006

Abstract

The aim of the present study was to investigation in vitro the effect of deficient bone-implant contact on the primary stability of a straight conical stem. Various possible deficient contact patterns were derived from surgical simulations. The effect of stair climbing loads on the bone-implant micromotion was firstly investigated using a finite element model and then an in vitro test aimed at assessing primary stability. It was found that if the surface features are prevented from biting dense bone in a few small but critical regions, stem primary stability is completely lost. These results suggest that the surface features used in the axisymmetric stem under investigation can be too sensitive to deficient contact conditions, and thus should be augmented with additional antirotational fins. Preliminary tests showed that a stem with the addition of such fins presents good primary stability in all tested conditions.
2006
On the biomechanical stability of cementless straight conical hip stems / Viceconti M.; Pancanti A.; Varini E.; Traina F.; Cristofolini L.. - In: PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS. PART H, JOURNAL OF ENGINEERING IN MEDICINE. - ISSN 0954-4119. - STAMPA. - 220:3(2006), pp. 473-480. [10.1243/09544119H06904]
Viceconti M.; Pancanti A.; Varini E.; Traina F.; Cristofolini L.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/33382
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 15
social impact