The use of amorphous Si-PIN diodes showed interesting applications in detector research. Due to their properties and cost effective value, these devices can be used as small dosimeters for fast and real time dose evaluation. The responses of two different detectors to the measurement of X-ray total air KERMA are compared and presented, with the goal to get a dosimetric parameter directly during the X-ray patients exposure. A bare Si-PIN diode and a Si-PIN diode+CsI(Tl) scintillator were tested and compared to radiologic dosimeters. Both detector outputs were calibrated using a secondary reference standard (CAPINTEC PM 30 dosimeter), in order to analyze and discuss the dose and the energy dependence of the detectors in the range of radiologic interest (tube voltage: 40–140 kVp and additional filtration: 0 mm Al to 4 mm Al). The bare Si-PIN diode shows a very coherent response independently from the X-ray beam quality and from the additional filtration. The Si-PIN+CsI(Tl) detector, on the other hand, shows a high spread of the calibration curves as a function of the tube high voltage and the additional filtration. The presented results could be used to calibrate an image detector in dose.

Comparison between a silicon PIN diode and a CsI(Tl) coupled to a silicon PIN diode for dosimetric purpose in radiology / Lucia Andreani;Marco Bontempi;Pier Luca Rossi;Luigi Pio Rignanese;Mirco Zuffa;Giuseppe Baldazzi. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 762:(2014), pp. 11-15. [10.1016/j.nima.2014.05.072]

Comparison between a silicon PIN diode and a CsI(Tl) coupled to a silicon PIN diode for dosimetric purpose in radiology

ANDREANI, LUCIA;ROSSI, PIER LUCA;Luigi Pio Rignanese;BALDAZZI, GIUSEPPE
2014

Abstract

The use of amorphous Si-PIN diodes showed interesting applications in detector research. Due to their properties and cost effective value, these devices can be used as small dosimeters for fast and real time dose evaluation. The responses of two different detectors to the measurement of X-ray total air KERMA are compared and presented, with the goal to get a dosimetric parameter directly during the X-ray patients exposure. A bare Si-PIN diode and a Si-PIN diode+CsI(Tl) scintillator were tested and compared to radiologic dosimeters. Both detector outputs were calibrated using a secondary reference standard (CAPINTEC PM 30 dosimeter), in order to analyze and discuss the dose and the energy dependence of the detectors in the range of radiologic interest (tube voltage: 40–140 kVp and additional filtration: 0 mm Al to 4 mm Al). The bare Si-PIN diode shows a very coherent response independently from the X-ray beam quality and from the additional filtration. The Si-PIN+CsI(Tl) detector, on the other hand, shows a high spread of the calibration curves as a function of the tube high voltage and the additional filtration. The presented results could be used to calibrate an image detector in dose.
2014
Comparison between a silicon PIN diode and a CsI(Tl) coupled to a silicon PIN diode for dosimetric purpose in radiology / Lucia Andreani;Marco Bontempi;Pier Luca Rossi;Luigi Pio Rignanese;Mirco Zuffa;Giuseppe Baldazzi. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 762:(2014), pp. 11-15. [10.1016/j.nima.2014.05.072]
Lucia Andreani;Marco Bontempi;Pier Luca Rossi;Luigi Pio Rignanese;Mirco Zuffa;Giuseppe Baldazzi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/302529
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 6
social impact