Dual-energy mammographic imaging experimental tests have been performed using a compact dichromatic imaging system based on a conventional x-ray tube, a mosaic crystal, and a 384-strip silicon detector equipped with full-custom electronics with single photon counting capability. For simulating mammal tissue, a three-component phantom, made of Plexiglass, polyethylene, and water, has been used. Images have been collected with three different pairs of x-ray energies: 16–32 keV, 18–36 keV, and 20–40 keV. A Monte Carlo simulation of the experiment has also been carried out using the MCNP-4C transport code. The Alvarez-Macovski algorithm has been applied both to experimental and simulated data to remove the contrast between two of the phantom materials so as to enhance the visibility of the third one.

Contrast cancellation technique applied to digital x-ray imaging using silicon strip detectors / C. Avila; J. Lopez; J. C. Sanabria; G. Baldazzi; D. Bollini; M. Gombia; A. E. Cabal; C. Ceballos; A. Diaz Garcia; M. Gambaccini; A. Taibi; A. Sarnelli; A. Tuffanelli; P. Giubellino; A. Marzari-Chiesa; F. Prino; E. Tomassi; P. Grybos; M. Idzik; K. Swientek; P. Wiacek; L. M. Montaño; L. Ramello; M. Sitta. - In: MEDICAL PHYSICS. - ISSN 0094-2405. - STAMPA. - 32:(2005), pp. 3755-3766. [10.1118/1.2126568]

Contrast cancellation technique applied to digital x-ray imaging using silicon strip detectors

BALDAZZI, GIUSEPPE;BOLLINI, DANTE;GOMBIA, MIRKO;
2005

Abstract

Dual-energy mammographic imaging experimental tests have been performed using a compact dichromatic imaging system based on a conventional x-ray tube, a mosaic crystal, and a 384-strip silicon detector equipped with full-custom electronics with single photon counting capability. For simulating mammal tissue, a three-component phantom, made of Plexiglass, polyethylene, and water, has been used. Images have been collected with three different pairs of x-ray energies: 16–32 keV, 18–36 keV, and 20–40 keV. A Monte Carlo simulation of the experiment has also been carried out using the MCNP-4C transport code. The Alvarez-Macovski algorithm has been applied both to experimental and simulated data to remove the contrast between two of the phantom materials so as to enhance the visibility of the third one.
2005
Contrast cancellation technique applied to digital x-ray imaging using silicon strip detectors / C. Avila; J. Lopez; J. C. Sanabria; G. Baldazzi; D. Bollini; M. Gombia; A. E. Cabal; C. Ceballos; A. Diaz Garcia; M. Gambaccini; A. Taibi; A. Sarnelli; A. Tuffanelli; P. Giubellino; A. Marzari-Chiesa; F. Prino; E. Tomassi; P. Grybos; M. Idzik; K. Swientek; P. Wiacek; L. M. Montaño; L. Ramello; M. Sitta. - In: MEDICAL PHYSICS. - ISSN 0094-2405. - STAMPA. - 32:(2005), pp. 3755-3766. [10.1118/1.2126568]
C. Avila; J. Lopez; J. C. Sanabria; G. Baldazzi; D. Bollini; M. Gombia; A. E. Cabal; C. Ceballos; A. Diaz Garcia; M. Gambaccini; A. Taibi; A. Sarnelli; A. Tuffanelli; P. Giubellino; A. Marzari-Chiesa; F. Prino; E. Tomassi; P. Grybos; M. Idzik; K. Swientek; P. Wiacek; L. M. Montaño; L. Ramello; M. Sitta
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/24905
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 20
social impact