PURPOSE: To report a clinical case of dental implant rehabilitation of an atrophic posterior mandible with the usage of a new alveolar distraction protocol. MATERIALS AND METHODS: A posterior atrophic mandible was treated with distraction osteogenesis; after the first phase of latency (10 days), the activation phase (24 days), and the consolidation phase (30 days), the distractor was removed, and 2 implants were placed; 4 months thereafter, the fixtures were provisionally loaded. RESULTS: No complications were recorded during the treatment. At the end of the activation phase, a mean of 5 mm of vertical bone augmentation was obtained, and it allowed the placement of two 10-mm long fixtures. No periimplant bone resorption was detected at the time of definitive prosthetic loading. CONCLUSIONS: The proposed protocol secured a sound prosthetic rehabilitation on an otherwise atrophied posterior mandible so as to avoid grafting procedures.

Alveolar distraction osteogenesis in posterior atrophic mandible: a case report on a new technical approach / Felice P;Lizio G;Checchi L. - In: IMPLANT DENTISTRY. - ISSN 1056-6163. - ELETTRONICO. - 22:(2013), pp. 332-338. [10.1097/ID.0b013e31829c225f]

Alveolar distraction osteogenesis in posterior atrophic mandible: a case report on a new technical approach.

FELICE, PIETRO;LIZIO, GIUSEPPE;CHECCHI, LUIGI
2013

Abstract

PURPOSE: To report a clinical case of dental implant rehabilitation of an atrophic posterior mandible with the usage of a new alveolar distraction protocol. MATERIALS AND METHODS: A posterior atrophic mandible was treated with distraction osteogenesis; after the first phase of latency (10 days), the activation phase (24 days), and the consolidation phase (30 days), the distractor was removed, and 2 implants were placed; 4 months thereafter, the fixtures were provisionally loaded. RESULTS: No complications were recorded during the treatment. At the end of the activation phase, a mean of 5 mm of vertical bone augmentation was obtained, and it allowed the placement of two 10-mm long fixtures. No periimplant bone resorption was detected at the time of definitive prosthetic loading. CONCLUSIONS: The proposed protocol secured a sound prosthetic rehabilitation on an otherwise atrophied posterior mandible so as to avoid grafting procedures.
2013
Alveolar distraction osteogenesis in posterior atrophic mandible: a case report on a new technical approach / Felice P;Lizio G;Checchi L. - In: IMPLANT DENTISTRY. - ISSN 1056-6163. - ELETTRONICO. - 22:(2013), pp. 332-338. [10.1097/ID.0b013e31829c225f]
Felice P;Lizio G;Checchi L
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/189887
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 8
social impact