Antioxidant activity of vegetable extracts is related to the nature and the amount of active components, mainly polyphenols; therefore, a correct quantification of these molecules should be required to define their concentration in such kind of vegetable extracts. A fast and accurate method to calculate molar absorption coefficients (ε), by using HPLC, has been tested on standard polyphenols and caffeine, and should be widely adapted for standardless quantitative analysis. Molar absorptivity (ε) of carnosic acid (CA) was determined from 200 to 300 nm, by the proposed method and those values were compared to tert-butyl-hydroxytoluene (BHT) ones for further comparative quantification

Calculation of the molar absorptivity of polyphenols by using liquid chromatography with diode array detection: the case of carnosic acid / PELILLO M.; CUVELIER M.E.; BIGUZZI B.; GALLINA TOSCHI T.; BERSET C.; LERCKER G.. - In: JOURNAL OF CHROMATOGRAPHY A. - ISSN 0021-9673. - STAMPA. - 1023:(2004), pp. 225-229. [10.1016/S0021-9673(03)01206-8]

Calculation of the molar absorptivity of polyphenols by using liquid chromatography with diode array detection: the case of carnosic acid

PELILLO, MARCO;BIGUZZI, BARBARA;GALLINA TOSCHI, TULLIA;LERCKER, GIOVANNI
2004

Abstract

Antioxidant activity of vegetable extracts is related to the nature and the amount of active components, mainly polyphenols; therefore, a correct quantification of these molecules should be required to define their concentration in such kind of vegetable extracts. A fast and accurate method to calculate molar absorption coefficients (ε), by using HPLC, has been tested on standard polyphenols and caffeine, and should be widely adapted for standardless quantitative analysis. Molar absorptivity (ε) of carnosic acid (CA) was determined from 200 to 300 nm, by the proposed method and those values were compared to tert-butyl-hydroxytoluene (BHT) ones for further comparative quantification
2004
Calculation of the molar absorptivity of polyphenols by using liquid chromatography with diode array detection: the case of carnosic acid / PELILLO M.; CUVELIER M.E.; BIGUZZI B.; GALLINA TOSCHI T.; BERSET C.; LERCKER G.. - In: JOURNAL OF CHROMATOGRAPHY A. - ISSN 0021-9673. - STAMPA. - 1023:(2004), pp. 225-229. [10.1016/S0021-9673(03)01206-8]
PELILLO M.; CUVELIER M.E.; BIGUZZI B.; GALLINA TOSCHI T.; BERSET C.; LERCKER G.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/1775
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 9
  • Scopus 49
  • ???jsp.display-item.citation.isi??? 46
social impact