In the instruments dedicated to the characterization of transient disturbances affecting the power supply, an event detection block activates the storage and processing functions only when necessary. In a previous contribution, the authors described a simple, robust and fast algorithm, which can easily be loaded on a DSP board to implement the above block. In this paper, the algorithm performance is investigated with special attention to its limitations. Optimization rules are provided and the results of experimental tests are reported and discussed.

Performance Analysis and Optimization of a Robust Algorithm for Voltage Transients Detection

PERETTO, LORENZO;ARTIOLI, MARCELLO;PASINI, GAETANO;SASDELLI, RENATO
2004

Abstract

In the instruments dedicated to the characterization of transient disturbances affecting the power supply, an event detection block activates the storage and processing functions only when necessary. In a previous contribution, the authors described a simple, robust and fast algorithm, which can easily be loaded on a DSP board to implement the above block. In this paper, the algorithm performance is investigated with special attention to its limitations. Optimization rules are provided and the results of experimental tests are reported and discussed.
2004
Proc. of the 21st IEEE Instrumentation and Measurement Technology Conference
2004
2009
L. Peretto; M. Artioli; G. Pasini; R. Sasdelli
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/17179
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact