Low-frequency dispersive phenomena due to self-heating and/or “traps” (that is, surface-state densities and deep-level traps) cause important dynamic deviations in the I/V characteristics of III-V devices and they must be taken into account when an accurate large-signal dynamic model is needed. To this end, different low-frequency dispersive I/V models have been proposed by the research community and, quite often, a characterization based on pulsed I/V measurement systems has been suggested as the most appropriate for the identification of model parameters. Unfortunately, besides requiring special-purpose setups, pulsed characterization may suffer from some drawbacks, as discussed in this article. As an alternative, a simple large-signal measurement setup is presented here, which is based on low-frequency sinusoidal excitations and can be easily implemented by means of conventional general-purpose laboratory instrumentation. The proposed setup is successfully adopted in this article to identify the dispersive I/V characteristics of a GaAs PHEMT large-signal model providing excellent prediction of intermodulation distortion at Ka-band frequencies.

Accurate modeling of electron device I/V characteristics through a simplified large-signal measurement setup

SANTARELLI, ALBERTO;TRAVERSO, PIER ANDREA;FILICORI, FABIO
2005

Abstract

Low-frequency dispersive phenomena due to self-heating and/or “traps” (that is, surface-state densities and deep-level traps) cause important dynamic deviations in the I/V characteristics of III-V devices and they must be taken into account when an accurate large-signal dynamic model is needed. To this end, different low-frequency dispersive I/V models have been proposed by the research community and, quite often, a characterization based on pulsed I/V measurement systems has been suggested as the most appropriate for the identification of model parameters. Unfortunately, besides requiring special-purpose setups, pulsed characterization may suffer from some drawbacks, as discussed in this article. As an alternative, a simple large-signal measurement setup is presented here, which is based on low-frequency sinusoidal excitations and can be easily implemented by means of conventional general-purpose laboratory instrumentation. The proposed setup is successfully adopted in this article to identify the dispersive I/V characteristics of a GaAs PHEMT large-signal model providing excellent prediction of intermodulation distortion at Ka-band frequencies.
2005
Raffo A.; Santarelli A.; Traverso P. A.; Pagani M.; Vannini G.; Filicori F.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/16054
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 5
social impact