A set of eighty-one extra virgin olive oils (EVOOs) was analysed according to the new quality parameters relative to the total amount of methyl and ethyl esters of fatty acids [Σ (FAMEs + FAEEs)] and the ratio between ethyl and methyl esters [ratio of FAEEs/FAMEs (RFF)]. Acquisition of the midinfrared spectra was also performed by Fourier Transform Infrared Spectroscopy (FT-IR). Chemical and spectroscopy data were chemometrically elaborated, and FT-IR coupled by Partial Least Square (PLS) methodology was developed. Results were statistically similar to official procedure in terms of analytical performance for Σ (FAMEs + FAEEs) and RFF in EVOOs: a good agreement between predicted and actual values on calibration data sets was found (0.98 and 0.83, respectively) and the limit of quantification was low enough (29.3 mg kg-1) considering the actual limits for Σ (FAMEs + FAEEs). This new approach, time-saving and environmentally friendly, can be considered as a useful tool for screening procedures.

Detection of low-quality extra virgin olive oils by fatty acid alkyl esters evaluation: a preliminary and fast mid-infrared spectroscopy discrimination by a chemometric approach / Valli E.; Bendini A.; Ruben M. M.; Cerretani L.; Gallina Toschi T.; Casiraghi E.; Lercker G.. - In: INTERNATIONAL JOURNAL OF FOOD SCIENCE & TECHNOLOGY. - ISSN 0950-5423. - STAMPA. - 48:(2013), pp. 548-555. [10.1111/j.1365-2621.2012.03220.x]

Detection of low-quality extra virgin olive oils by fatty acid alkyl esters evaluation: a preliminary and fast mid-infrared spectroscopy discrimination by a chemometric approach

VALLI, ENRICO;BENDINI, ALESSANDRA;CERRETANI, LORENZO;GALLINA TOSCHI, TULLIA;LERCKER, GIOVANNI
2013

Abstract

A set of eighty-one extra virgin olive oils (EVOOs) was analysed according to the new quality parameters relative to the total amount of methyl and ethyl esters of fatty acids [Σ (FAMEs + FAEEs)] and the ratio between ethyl and methyl esters [ratio of FAEEs/FAMEs (RFF)]. Acquisition of the midinfrared spectra was also performed by Fourier Transform Infrared Spectroscopy (FT-IR). Chemical and spectroscopy data were chemometrically elaborated, and FT-IR coupled by Partial Least Square (PLS) methodology was developed. Results were statistically similar to official procedure in terms of analytical performance for Σ (FAMEs + FAEEs) and RFF in EVOOs: a good agreement between predicted and actual values on calibration data sets was found (0.98 and 0.83, respectively) and the limit of quantification was low enough (29.3 mg kg-1) considering the actual limits for Σ (FAMEs + FAEEs). This new approach, time-saving and environmentally friendly, can be considered as a useful tool for screening procedures.
2013
Detection of low-quality extra virgin olive oils by fatty acid alkyl esters evaluation: a preliminary and fast mid-infrared spectroscopy discrimination by a chemometric approach / Valli E.; Bendini A.; Ruben M. M.; Cerretani L.; Gallina Toschi T.; Casiraghi E.; Lercker G.. - In: INTERNATIONAL JOURNAL OF FOOD SCIENCE & TECHNOLOGY. - ISSN 0950-5423. - STAMPA. - 48:(2013), pp. 548-555. [10.1111/j.1365-2621.2012.03220.x]
Valli E.; Bendini A.; Ruben M. M.; Cerretani L.; Gallina Toschi T.; Casiraghi E.; Lercker G.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/133497
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 20
social impact