Topiramate (2,3:4,5-bis-O −(1-methylethylidene)-D-fructopyranose sulfamate) is one of the most recent anticonvulsant agents introduced in the market. It seems to act as a sodium channel blocker and a chloride channel activator, but its exact mechanism of action is still unclear. While it is generally considered safer than other, older drugs (such as carbamazepine, valproate or barbiturates), its use can still cause severe side effects: during chronic treatment, patients can suffer from vision loss (glaucoma, myopia), osteoporosis, hyperthermia and nephrolithiasis. In order to achieve optimal therapeutic efficacy and to reduce the incidence of side and toxic effects, therapeutic drug monitoring (TDM) of patients undergoing treatment with topiramate is clearly advisable. Two original methods were developed and compared for the TDM of topiramate: one based on HPLC with fluorescence detection and one based on capillary electrophoresis (CE) with indirect UV detection. Topiramate does not possess significant chromophores, thus it has extremely low UV-visible absorbance and no spontaneous fluorescence. In order to achieve sufficient sensitivity, the analyte was derivatised with dansyl chloride before HPLC analysis, while indirect UV detection was implemented for CE, using sulfamethoxazole as the absorbance probe. Both analytical methods were fully validated. HPLC-F is somewhat more complicated and time-consuming, due to the derivatisation procedure, but has also better precision and extraction yields. It has also the advantage of allowing the determination of other low-absorbing antiepileptics, such as gabapentin and vigabatrin. The CE method, on the other hand, has the advantage of requiring much lower volumes of sample and of expensive and polluting solvents. The methods have demonstrated to be suitable for the monitoring of patients undergoing therapy with topiramate. They can be used alternatively, according to the needs of the analysis and other considerations, such the potential for interference of other co-administered drugs.

Comparison of CE and HPLC for therapeutic drug monitoring of the antiepileptic drug topiramate / Mandrioli R.; Mercolini L.; Ghedini N.; Amore M.; Kenndler E.; Raggi M.A.. - In: PHARMACOPSYCHIATRY. - ISSN 0176-3679. - STAMPA. - 44:(2011), pp. 279-279. [10.1055/s-0031-1292306]

Comparison of CE and HPLC for therapeutic drug monitoring of the antiepileptic drug topiramate.

MANDRIOLI, ROBERTO;MERCOLINI, LAURA;GHEDINI, NADIA;RAGGI, MARIA AUGUSTA
2011

Abstract

Topiramate (2,3:4,5-bis-O −(1-methylethylidene)-D-fructopyranose sulfamate) is one of the most recent anticonvulsant agents introduced in the market. It seems to act as a sodium channel blocker and a chloride channel activator, but its exact mechanism of action is still unclear. While it is generally considered safer than other, older drugs (such as carbamazepine, valproate or barbiturates), its use can still cause severe side effects: during chronic treatment, patients can suffer from vision loss (glaucoma, myopia), osteoporosis, hyperthermia and nephrolithiasis. In order to achieve optimal therapeutic efficacy and to reduce the incidence of side and toxic effects, therapeutic drug monitoring (TDM) of patients undergoing treatment with topiramate is clearly advisable. Two original methods were developed and compared for the TDM of topiramate: one based on HPLC with fluorescence detection and one based on capillary electrophoresis (CE) with indirect UV detection. Topiramate does not possess significant chromophores, thus it has extremely low UV-visible absorbance and no spontaneous fluorescence. In order to achieve sufficient sensitivity, the analyte was derivatised with dansyl chloride before HPLC analysis, while indirect UV detection was implemented for CE, using sulfamethoxazole as the absorbance probe. Both analytical methods were fully validated. HPLC-F is somewhat more complicated and time-consuming, due to the derivatisation procedure, but has also better precision and extraction yields. It has also the advantage of allowing the determination of other low-absorbing antiepileptics, such as gabapentin and vigabatrin. The CE method, on the other hand, has the advantage of requiring much lower volumes of sample and of expensive and polluting solvents. The methods have demonstrated to be suitable for the monitoring of patients undergoing therapy with topiramate. They can be used alternatively, according to the needs of the analysis and other considerations, such the potential for interference of other co-administered drugs.
2011
Comparison of CE and HPLC for therapeutic drug monitoring of the antiepileptic drug topiramate / Mandrioli R.; Mercolini L.; Ghedini N.; Amore M.; Kenndler E.; Raggi M.A.. - In: PHARMACOPSYCHIATRY. - ISSN 0176-3679. - STAMPA. - 44:(2011), pp. 279-279. [10.1055/s-0031-1292306]
Mandrioli R.; Mercolini L.; Ghedini N.; Amore M.; Kenndler E.; Raggi M.A.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/133092
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 0
social impact