The paper compares a transmission line (TL) approach with the finite element method (FEM) for the calculation of the lightning-originated surges on overhead power lines due to nearby lightning return strokes. Both the lightning electromagnetic pulse (LEMP) and the induced voltages in an overhead line are calculated by using the developed FEM model. The LEMP waveforms are provided as inputs to the computer code that implements a LEMP-to-transmission line coupling model. The comparison between the induced voltages calculated by using the two different approaches is repeated for the case of an overhead line above a perfectly conducting ground, with and without the shielding effect of building placed along the line, and for the case of lossy ground. The paper identifies and discusses the main causes of discrepancy between the obtained results.

On the FEM and TL approaches for the calculation of lightning - induced voltages on overhead lines / F. Napolitano; A. Borghetti; C. A. Nucci; M. Paolone; F. Rachidi. - ELETTRONICO. - (2012), pp. 74-1-71-4. (Intervento presentato al convegno 8th Mediterranean Conference on Power Generation, Transmission, Distribution and Energy Conversion (MEDPOWER 2012) tenutosi a Cagliari, Italy nel 1-3 Oct. 2012) [10.1049/cp.2012.2050].

On the FEM and TL approaches for the calculation of lightning - induced voltages on overhead lines

NAPOLITANO, FABIO;BORGHETTI, ALBERTO;NUCCI, CARLO ALBERTO;
2012

Abstract

The paper compares a transmission line (TL) approach with the finite element method (FEM) for the calculation of the lightning-originated surges on overhead power lines due to nearby lightning return strokes. Both the lightning electromagnetic pulse (LEMP) and the induced voltages in an overhead line are calculated by using the developed FEM model. The LEMP waveforms are provided as inputs to the computer code that implements a LEMP-to-transmission line coupling model. The comparison between the induced voltages calculated by using the two different approaches is repeated for the case of an overhead line above a perfectly conducting ground, with and without the shielding effect of building placed along the line, and for the case of lossy ground. The paper identifies and discusses the main causes of discrepancy between the obtained results.
2012
Conference Proceedings - 8th Mediterranean Conference on Power Generation, Transmission, Distribution and Energy Conversion MEDPOWER 2012
74-1
71-4
On the FEM and TL approaches for the calculation of lightning - induced voltages on overhead lines / F. Napolitano; A. Borghetti; C. A. Nucci; M. Paolone; F. Rachidi. - ELETTRONICO. - (2012), pp. 74-1-71-4. (Intervento presentato al convegno 8th Mediterranean Conference on Power Generation, Transmission, Distribution and Energy Conversion (MEDPOWER 2012) tenutosi a Cagliari, Italy nel 1-3 Oct. 2012) [10.1049/cp.2012.2050].
F. Napolitano; A. Borghetti; C. A. Nucci; M. Paolone; F. Rachidi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/128867
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact