PURPOSE: To retrospectively evaluate and compare (18)F-FDG, (18)F-DOPA and (68)Ga-somatostatin analogues for PET/CT in patients with residual/recurrent medullary thyroid carcinoma (MTC) suspected on the basis of elevated serum calcitonin levels. METHODS: Included in the study were 18 patients with recurrent MTC in whom functional imaging with the three tracers was performed. The PET/CT results were compared on a per-patient basis and on a per-lesion-basis. RESULTS: At least one focus of abnormal uptake was observed on PET/CT in 13 patients with (18)F-DOPA (72.2% sensitivity), in 6 patients with (68)Ga-somatostatin analogues (33.3%) and in 3 patients with (18)F-FDG (16.7%) (p < 0.01). There was a statistically significant difference in sensitivity between (18)F-DOPA and (18)F-FDG PET/CT (p < 0.01) and between (18)F-DOPA and (68)Ga-somatostatin analogue PET/CT (p = 0.04). Overall, 72 lesions were identified on PET/CT with the three tracers. (18)F-DOPA PET/CT detected 85% of lesions (61 of 72), (68)Ga-somatostatin analogue PET/CT 20% (14 of 72) and (18)F-FDG PET/CT 28% (20 of 72). There was a statistically significant difference in the number of lymph node, liver and bone lesions detected with the three tracers (p < 0.01). In particular, post-hoc tests showed a significant difference in the number of lymph node, liver and bone lesions detected by (18)F-DOPA PET/CT and (18)F-FDG PET/CT (p < 0.01 for all the analyses) and by (18)F-DOPA PET/CT and (68)Ga-somatostatin analogue PET/CT (p < 0.01 for all the analyses). The PET/CT results led to a change in management of eight patients (44%). CONCLUSION: (18)F-DOPA PET/CT seems to be the most useful imaging method for detecting recurrent MTC lesions in patients with elevated serum calcitonin levels, performing better than (18)F-FDG and (68)Ga-somatostatin analogue PET/CT. (18)F-FDG may complement (18)F-DOPA in patients with an aggressive tumour.

Comparison of 18F-DOPA, 18F-FDG and 68Ga-somatostatin analogue PET/CT in patients with recurrent medullary thyroid carcinoma / Treglia G; Castaldi P; Villani MF; Perotti G; de Waure C; Filice A; Ambrosini V; Cremonini N; Santimaria M; Versari A; Fanti S; Giordano A; Rufini V.. - In: EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING. - ISSN 1619-7070. - STAMPA. - 39:(2012), pp. 569-580. [10.1007/s00259-011-2031-6]

Comparison of 18F-DOPA, 18F-FDG and 68Ga-somatostatin analogue PET/CT in patients with recurrent medullary thyroid carcinoma

AMBROSINI, VALENTINA;FANTI, STEFANO;
2012

Abstract

PURPOSE: To retrospectively evaluate and compare (18)F-FDG, (18)F-DOPA and (68)Ga-somatostatin analogues for PET/CT in patients with residual/recurrent medullary thyroid carcinoma (MTC) suspected on the basis of elevated serum calcitonin levels. METHODS: Included in the study were 18 patients with recurrent MTC in whom functional imaging with the three tracers was performed. The PET/CT results were compared on a per-patient basis and on a per-lesion-basis. RESULTS: At least one focus of abnormal uptake was observed on PET/CT in 13 patients with (18)F-DOPA (72.2% sensitivity), in 6 patients with (68)Ga-somatostatin analogues (33.3%) and in 3 patients with (18)F-FDG (16.7%) (p < 0.01). There was a statistically significant difference in sensitivity between (18)F-DOPA and (18)F-FDG PET/CT (p < 0.01) and between (18)F-DOPA and (68)Ga-somatostatin analogue PET/CT (p = 0.04). Overall, 72 lesions were identified on PET/CT with the three tracers. (18)F-DOPA PET/CT detected 85% of lesions (61 of 72), (68)Ga-somatostatin analogue PET/CT 20% (14 of 72) and (18)F-FDG PET/CT 28% (20 of 72). There was a statistically significant difference in the number of lymph node, liver and bone lesions detected with the three tracers (p < 0.01). In particular, post-hoc tests showed a significant difference in the number of lymph node, liver and bone lesions detected by (18)F-DOPA PET/CT and (18)F-FDG PET/CT (p < 0.01 for all the analyses) and by (18)F-DOPA PET/CT and (68)Ga-somatostatin analogue PET/CT (p < 0.01 for all the analyses). The PET/CT results led to a change in management of eight patients (44%). CONCLUSION: (18)F-DOPA PET/CT seems to be the most useful imaging method for detecting recurrent MTC lesions in patients with elevated serum calcitonin levels, performing better than (18)F-FDG and (68)Ga-somatostatin analogue PET/CT. (18)F-FDG may complement (18)F-DOPA in patients with an aggressive tumour.
2012
Comparison of 18F-DOPA, 18F-FDG and 68Ga-somatostatin analogue PET/CT in patients with recurrent medullary thyroid carcinoma / Treglia G; Castaldi P; Villani MF; Perotti G; de Waure C; Filice A; Ambrosini V; Cremonini N; Santimaria M; Versari A; Fanti S; Giordano A; Rufini V.. - In: EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING. - ISSN 1619-7070. - STAMPA. - 39:(2012), pp. 569-580. [10.1007/s00259-011-2031-6]
Treglia G; Castaldi P; Villani MF; Perotti G; de Waure C; Filice A; Ambrosini V; Cremonini N; Santimaria M; Versari A; Fanti S; Giordano A; Rufini V.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/118873
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 19
  • Scopus 125
  • ???jsp.display-item.citation.isi??? 108
social impact