Background And Purpose- In patients with atrial fibrillation (AF), stroke risk stratification schema do not consider AF parameters. The aim of the study is to assess the impact of combining risk factors with continuous AF burden monitoring. Methods- In this retrospective study 568 patients implanted with a DDDR-P pacemaker (AT-500; Medtronic) and a history of AF were continuously monitored for 1 year. Results- During follow-up, 14 patients (2.5%) had a thromboembolic event. Patients were divided into 3 groups: AF burden ≤5 minutes per day (AF-free; n=223 [39%]), AF burden >5 minutes but <24 hours per day (AF-5 minutes; n=179 [32%]), and AF burden 24 hours (AF-24 hours; n=166 [29%]). Patients were also classified according to CHADS2 and CHA2DS2-VASc risk scores. The discrimination ability of each risk score was evaluated performing a logistic regression analysis and calculating the corresponding C-statistic. The addition of AF burden improved C-statistics: for CHADS2 from 0.653 (P=0.051) to 0.713 (P=0.007); for CHA2DS2-VASc, from 0.898 (P<0.0001) to 0.910 (P<0.0001). Conclusions- The CHA2DS2-VASc score had a high sensitivity to predict thromboembolism. Implementation of device data on AF presence/duration/burden has the potential to contribute to improved clinical risk stratification and should be tested prospectively.

Improving stroke risk stratification using the CHADS2 and CHA2DS2-VASc risk scores in patients with paroxysmal atrial fibrillation by continuous arrhythmia burden monitoring / Boriani G; Botto GL; Padeletti L; Santini M; Capucci A; Gulizia M; Ricci R; Biffi M; De Santo T; Corbucci G; Lip GY; Italian AT-500 Registry Investigators.. - In: STROKE. - ISSN 0039-2499. - STAMPA. - 42:(2011), pp. 1768-1770. [10.1161/STROKEAHA.110.609297]

Improving stroke risk stratification using the CHADS2 and CHA2DS2-VASc risk scores in patients with paroxysmal atrial fibrillation by continuous arrhythmia burden monitoring.

BORIANI, GIUSEPPE;BIFFI, MAURO;
2011

Abstract

Background And Purpose- In patients with atrial fibrillation (AF), stroke risk stratification schema do not consider AF parameters. The aim of the study is to assess the impact of combining risk factors with continuous AF burden monitoring. Methods- In this retrospective study 568 patients implanted with a DDDR-P pacemaker (AT-500; Medtronic) and a history of AF were continuously monitored for 1 year. Results- During follow-up, 14 patients (2.5%) had a thromboembolic event. Patients were divided into 3 groups: AF burden ≤5 minutes per day (AF-free; n=223 [39%]), AF burden >5 minutes but <24 hours per day (AF-5 minutes; n=179 [32%]), and AF burden 24 hours (AF-24 hours; n=166 [29%]). Patients were also classified according to CHADS2 and CHA2DS2-VASc risk scores. The discrimination ability of each risk score was evaluated performing a logistic regression analysis and calculating the corresponding C-statistic. The addition of AF burden improved C-statistics: for CHADS2 from 0.653 (P=0.051) to 0.713 (P=0.007); for CHA2DS2-VASc, from 0.898 (P<0.0001) to 0.910 (P<0.0001). Conclusions- The CHA2DS2-VASc score had a high sensitivity to predict thromboembolism. Implementation of device data on AF presence/duration/burden has the potential to contribute to improved clinical risk stratification and should be tested prospectively.
2011
Improving stroke risk stratification using the CHADS2 and CHA2DS2-VASc risk scores in patients with paroxysmal atrial fibrillation by continuous arrhythmia burden monitoring / Boriani G; Botto GL; Padeletti L; Santini M; Capucci A; Gulizia M; Ricci R; Biffi M; De Santo T; Corbucci G; Lip GY; Italian AT-500 Registry Investigators.. - In: STROKE. - ISSN 0039-2499. - STAMPA. - 42:(2011), pp. 1768-1770. [10.1161/STROKEAHA.110.609297]
Boriani G; Botto GL; Padeletti L; Santini M; Capucci A; Gulizia M; Ricci R; Biffi M; De Santo T; Corbucci G; Lip GY; Italian AT-500 Registry Investigators.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/107167
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 45
  • Scopus 178
  • ???jsp.display-item.citation.isi??? 154
social impact