Abstract Based on the published results primarily from cohort studies, percutaneous lead extraction is now considered a safe procedure and indications for its use have broadened from device-related infections to less strict indications, such as recurrent isolated bacteremia, asymptomatic upper vein occlusion and malfunctioning/redundant leads. Almost 50% of electrophysiologists consider lead extraction in these latter situations. To broaden its implementation, further prospective evaluation against conservative approaches is still needed. Rather than only aiming at short-term results, this technique should be integrated into wide-ranging tailored long-term strategies to manage all of the different issues of implanted patients

From lead management to implanted patient management: indications to lead extraction in pacemaker and cardioverter-defibrillator systems / Diemberger I; Biffi M; Martignani C; Boriani G.. - In: EXPERT REVIEW OF MEDICAL DEVICES. - ISSN 1743-4440. - STAMPA. - 8:(2011), pp. 235-255. [10.1586/erd.10.80]

From lead management to implanted patient management: indications to lead extraction in pacemaker and cardioverter-defibrillator systems

DIEMBERGER, IGOR;BIFFI, MAURO;MARTIGNANI, CRISTIAN;BORIANI, GIUSEPPE
2011

Abstract

Abstract Based on the published results primarily from cohort studies, percutaneous lead extraction is now considered a safe procedure and indications for its use have broadened from device-related infections to less strict indications, such as recurrent isolated bacteremia, asymptomatic upper vein occlusion and malfunctioning/redundant leads. Almost 50% of electrophysiologists consider lead extraction in these latter situations. To broaden its implementation, further prospective evaluation against conservative approaches is still needed. Rather than only aiming at short-term results, this technique should be integrated into wide-ranging tailored long-term strategies to manage all of the different issues of implanted patients
2011
From lead management to implanted patient management: indications to lead extraction in pacemaker and cardioverter-defibrillator systems / Diemberger I; Biffi M; Martignani C; Boriani G.. - In: EXPERT REVIEW OF MEDICAL DEVICES. - ISSN 1743-4440. - STAMPA. - 8:(2011), pp. 235-255. [10.1586/erd.10.80]
Diemberger I; Biffi M; Martignani C; Boriani G.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/107166
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 41
  • ???jsp.display-item.citation.isi??? 36
social impact