The aim of the present study was to set-up a Fast gas chromatography/mass spectrometry method for the analysis of cholesterol oxidation products (COPs). A silylated mixture of seven oxysterol standards was injected into a Fast GC/MS system. A capillary GC column (10 m × 0.1 mm internal diameter × 0.1 μm film thickness) coated with 95% dimethyl- and 5% diphenyl-polysiloxane, was used. The method gave a fast (total analysis time= 3.5 min) and satisfactory resolution (R > 1.2) of the COPs standards, with a good repeatability and sensitivity, similar to those of conventional GC/MS; recoveries were tested on mice liver. Fast GC/MS method suitability for COPs analysis in food was also tested on an oxidized sardine fillet, which had been previously saponified and purified by NH2 solid phase extraction (SPE); a good repeatability and sensitivity was also obtained. The analytical performance of Fast GC/MS method for the determination of COPs, together with the consequent significant reduction of the analysis time and consumables, demonstrates that Fast GC/MS represents a valid alternative to conventional GC/MS and evinces the great potential of such analytical technique, which could be applied to both food and biological samples.

Analysis of cholesterol oxidation products by Fast gas chromatography/mass spectrometry / V. Cardenia; M. T. Rodriguez-Estrada; E. Baldacci; S. Savioli; G. Lercker. - In: JOURNAL OF SEPARATION SCIENCE. - ISSN 1615-9314. - ELETTRONICO. - 35:3(2012), pp. 424-430. [10.1002/jssc.201100660]

Analysis of cholesterol oxidation products by Fast gas chromatography/mass spectrometry

CARDENIA, VLADIMIRO;RODRIGUEZ ESTRADA, MARIA TERESA;SAVIOLI, STEFANO;LERCKER, GIOVANNI
2012

Abstract

The aim of the present study was to set-up a Fast gas chromatography/mass spectrometry method for the analysis of cholesterol oxidation products (COPs). A silylated mixture of seven oxysterol standards was injected into a Fast GC/MS system. A capillary GC column (10 m × 0.1 mm internal diameter × 0.1 μm film thickness) coated with 95% dimethyl- and 5% diphenyl-polysiloxane, was used. The method gave a fast (total analysis time= 3.5 min) and satisfactory resolution (R > 1.2) of the COPs standards, with a good repeatability and sensitivity, similar to those of conventional GC/MS; recoveries were tested on mice liver. Fast GC/MS method suitability for COPs analysis in food was also tested on an oxidized sardine fillet, which had been previously saponified and purified by NH2 solid phase extraction (SPE); a good repeatability and sensitivity was also obtained. The analytical performance of Fast GC/MS method for the determination of COPs, together with the consequent significant reduction of the analysis time and consumables, demonstrates that Fast GC/MS represents a valid alternative to conventional GC/MS and evinces the great potential of such analytical technique, which could be applied to both food and biological samples.
2012
Analysis of cholesterol oxidation products by Fast gas chromatography/mass spectrometry / V. Cardenia; M. T. Rodriguez-Estrada; E. Baldacci; S. Savioli; G. Lercker. - In: JOURNAL OF SEPARATION SCIENCE. - ISSN 1615-9314. - ELETTRONICO. - 35:3(2012), pp. 424-430. [10.1002/jssc.201100660]
V. Cardenia; M. T. Rodriguez-Estrada; E. Baldacci; S. Savioli; G. Lercker
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/106430
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 48
  • ???jsp.display-item.citation.isi??? 45
social impact