In this work the sound source directivity influence on the Reflection Index measurement has been investigated. Two different sound sources and two different noise barrier surfaces (absorptive and reflective) were used. The measurements have been performed following the CEN/TS 1793-5 European standard (“Adrienne” method) using a 3 x 3 microphone grid instead of the single microphone required by the standard. The loudspeaker has been rotated on the horizontal axis for both the “free field” and “on barrier” measurements, covering an angle of 180 degrees in steps of 10 degrees. The results clearly show that the source directivity has limited influence on the final measurement results and that the average of the measurement values on the grid is more accurate and reliable than the single microphone measurement. It is also shown that the signal subtraction can reliably be done without a rigid connection source-microphone(s).

Reflection index measurement on noise barriers with the Adrienne method: source directivity investigation and microphone grid implementation / Garai M.; Guidorzi P.. - ELETTRONICO. - 4:(2011), pp. 2851-2856. (Intervento presentato al convegno Inter-Noise 2011 tenutosi a Osaka nel 4-7 September 2011).

Reflection index measurement on noise barriers with the Adrienne method: source directivity investigation and microphone grid implementation

GARAI, MASSIMO;GUIDORZI, PAOLO
2011

Abstract

In this work the sound source directivity influence on the Reflection Index measurement has been investigated. Two different sound sources and two different noise barrier surfaces (absorptive and reflective) were used. The measurements have been performed following the CEN/TS 1793-5 European standard (“Adrienne” method) using a 3 x 3 microphone grid instead of the single microphone required by the standard. The loudspeaker has been rotated on the horizontal axis for both the “free field” and “on barrier” measurements, covering an angle of 180 degrees in steps of 10 degrees. The results clearly show that the source directivity has limited influence on the final measurement results and that the average of the measurement values on the grid is more accurate and reliable than the single microphone measurement. It is also shown that the signal subtraction can reliably be done without a rigid connection source-microphone(s).
2011
Proceedings of Inter-Noise 2011
2851
2856
Reflection index measurement on noise barriers with the Adrienne method: source directivity investigation and microphone grid implementation / Garai M.; Guidorzi P.. - ELETTRONICO. - 4:(2011), pp. 2851-2856. (Intervento presentato al convegno Inter-Noise 2011 tenutosi a Osaka nel 4-7 September 2011).
Garai M.; Guidorzi P.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/106234
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? ND
social impact