A sensitive and selective reversed-phase liquid chromatographic (RP-LC) method was developed and validated to determine octopamine, tyramine and Tyrosine (Tyr) in complex matrices as formulations and phytoextracts (Citrus aurantium), after pre-column derivatization with o-phthaldialdehyde (OPA) reagent. The chromatographic separations were performed at room temperature on a Phenomenex Luna C18 column using methanol and sodium acetate buffer (pH 5.5) by varying composition gradient elution as mobile phase and detected flurometrically at λem = 455 nm with λex = 340 nm. The results obtained by the proposed method were compared with those achieved by a validated direct RP-LC method with fluorescence detection at λem = 310 nm with λex = 275 nm, as reference method, using a Phenomenex Gemini C18 column under isocratic elution conditions with acetonitrile and sodium 1-heptanesulphonate (pH 3), as mobile phase. The higher sensitivity of the derivatization method (detection limit about 0.06 pmol) allowed the sure determination of octopamine present in traces in the examined samples. The repeatability of method (RSD) was ≤1.90% and there was no significant difference between repeatability and intermediate precision data. Recovery studies showed good results 99.5–101.3% with RSD ranging from 0.8 to 1.2%. All analyses were performed by mild conditions in absence of preliminary difficult extraction methodologies or laborious step of sample pre-treatment.

Development and validation of a pre-column reversed phase liquid chromatographic method with fluorescence detection for the determination of primary phenethylamines in dietary supplements and phytoextracts / R. Gatti*; C. Lotti. - In: JOURNAL OF CHROMATOGRAPHY A. - ISSN 0021-9673. - STAMPA. - 1218:28(2011), pp. 4468-4473. [10.1016/j.chroma.2011.05.044]

Development and validation of a pre-column reversed phase liquid chromatographic method with fluorescence detection for the determination of primary phenethylamines in dietary supplements and phytoextracts

GATTI, RITA;LOTTI, CINZIA
2011

Abstract

A sensitive and selective reversed-phase liquid chromatographic (RP-LC) method was developed and validated to determine octopamine, tyramine and Tyrosine (Tyr) in complex matrices as formulations and phytoextracts (Citrus aurantium), after pre-column derivatization with o-phthaldialdehyde (OPA) reagent. The chromatographic separations were performed at room temperature on a Phenomenex Luna C18 column using methanol and sodium acetate buffer (pH 5.5) by varying composition gradient elution as mobile phase and detected flurometrically at λem = 455 nm with λex = 340 nm. The results obtained by the proposed method were compared with those achieved by a validated direct RP-LC method with fluorescence detection at λem = 310 nm with λex = 275 nm, as reference method, using a Phenomenex Gemini C18 column under isocratic elution conditions with acetonitrile and sodium 1-heptanesulphonate (pH 3), as mobile phase. The higher sensitivity of the derivatization method (detection limit about 0.06 pmol) allowed the sure determination of octopamine present in traces in the examined samples. The repeatability of method (RSD) was ≤1.90% and there was no significant difference between repeatability and intermediate precision data. Recovery studies showed good results 99.5–101.3% with RSD ranging from 0.8 to 1.2%. All analyses were performed by mild conditions in absence of preliminary difficult extraction methodologies or laborious step of sample pre-treatment.
2011
Development and validation of a pre-column reversed phase liquid chromatographic method with fluorescence detection for the determination of primary phenethylamines in dietary supplements and phytoextracts / R. Gatti*; C. Lotti. - In: JOURNAL OF CHROMATOGRAPHY A. - ISSN 0021-9673. - STAMPA. - 1218:28(2011), pp. 4468-4473. [10.1016/j.chroma.2011.05.044]
R. Gatti*; C. Lotti
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/102945
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 20
social impact